GENERAL SAfETY RULES

SPECifiC SAfETY RULES

 

know your inflator. 

Read operator’s manual carefully. 

Learn its applications and limitations, as well as the spe-
cific potential hazards related to this tool. Following this 
rule will reduce the risk of electric shock, fire, or serious 
injury.

 

Risk of Bursting. 

Do not preset inflator to result in output 

pressure greater than marked maximum pressure of item 
to be inflated. Do not use at pressure greater than 150 
PSI.

 

To reduce the risk of electric shock,

 do not expose to 

rain. Store indoors.

 

inspect yearly for cracks, pin holes, or other imper-
fections that could cause inflator to become unsafe. 

Never cut or drill holes in the inflator.

 

Make sure the hose is free of obstructions or snags.

 

Entangled or snarled hoses can cause loss of balance or 
footing and may become damaged. 

 

Use the inflator only for its intended use. Do not alter 
or modify the unit from the original design or func-
tion.

 

Always be aware that misuse and improper handling of 
this inflator can cause injury to yourself and others.

 

Never leave a inflator unattended with the air hose 
attached.

 

Do not continue to use a inflator or hose that leaks 
air or does not function properly.

 

Always disconnect the air supply and power supply 
before  making  adjustments,  servicing  a  inflator,  or 
when an inflator is not in use.

 

Do  not  attempt  to  pull  or  carry  the  inflator  by  the 
hoses.

 

Always follow all safety rules recommended by the 
manufacturer of your inflator, in addition to all safety 
rules for the inflator. 

Following this rule will reduce the 

risk of serious personal injury.

 

Do not use inflator as a breathing device.

 

Never direct a jet of compressed air toward people or 
animals. Take care not to blow dust and dirt towards 
yourself or others. 

Following this rule will reduce the risk 

of serious injury.

 

Protect  your  lungs. 

Wear  a  face  or  dust  mask  if  the 

operation is dusty. Following this rule will reduce the risk 
of serious personal injury.

 

Do not use this inflator to spray chemicals. 

Your lungs 

can be damaged by inhaling toxic fumes. 

 

Check damaged parts. Before further use of the infla-
tor or air tool, a guard or other part that is damaged 
should be carefully checked to determine that it will 
operate properly and perform its intended function. 
Check for alignment of moving parts, binding of mov-
ing parts, breakage of parts, mounting, and any other 
conditions that may affect its operation. A guard or 
other part that is damaged should be properly repaired 
or replaced by an authorized service center. 

Follow-

ing this rule will reduce the risk of shock, fire, or serious 
injury.

  

Do not crush, drop or damage battery pack. Do not 
use a battery pack or charger that has been dropped 
or received a sharp blow. 

A damaged battery is subject 

to explosion. Properly dispose of a dropped or damaged 
battery immediately.

 

Do  not  charge  battery  tool  in  a  damp  or  wet 

location. 

Following this rule will reduce the risk of electric 

shock.

 

inspect tool cords periodically and, if damaged, have 
repaired at your nearest Authorized Service Center. 
Constantly stay aware of cord location. 

Following this 

rule will reduce the risk of electric shock or fire.

 

Save these instructions. 

Refer to them frequently and 

use them to instruct others who may use this inflator. If 
you loan someone this inflator, loan them these instruc-
tions also.

 

Never point any inflator toward yourself or others.

 

keep the exterior of the inflator dry, clean, and free 
from  oil  and  grease.

  Always  use  a  clean  cloth  when 

cleaning.  Never  use  brake  fluids,  gasoline,  petroleum-
based products, or any strong solvents to clean the unit. 
Following this rule will reduce the risk of deterioration of 
the enclosure plastic.

 

Do not exceed the pressure rating of any component 
in the system. 

 

Protect material lines and air lines from damage or 
puncture.

 Keep hose and power cord away from sharp 

objects, chemical spills, oil, solvents, and wet floors.

SERviCE

 

inflator service must be performed only by qualified 
repair personnel. 

Service or maintenance performed by 

unqualified personnel may result in a risk of injury.

 

When servicing an inflator, use only identical replace-
ment parts. follow instructions in the Maintenance 
section  of  this  manual.

  Use  of  unauthorized  parts  or 

failure to follow Maintenance Instructions may create a 
risk of shock or injury.

Summary of Contents for P730

Page 1: ...to our high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product Thank you for your purchase BATTERIES AND CHARGERS SOLD SEPERATELY ...

Page 2: ...years HOW TO GET SERVICE Just return the power tool properly packaged and postage prepaid to an Authorized Service Center You can obtain the location of the Service Center nearest you by contacting a service representative at One World Technologies Inc P O Box 1207 Anderson SC 29622 1207 by calling 1 800 525 2579 or by logging on to www ryobitools com When you request warranty service you must als...

Page 3: ...to guard against flying fasteners and debris which could cause severe eye injury Do not wear loose clothing or jewelry Contain long hair Loose clothes jewelry or long hair can be drawn into air vents Do not use on a ladder or unstable support Stable footing on a solid surface enables better control of the inflator in unexpected situations TOOL USE AND CARE Do not force the tool Use the correct too...

Page 4: ...eck damaged parts Before further use of the infla tor or air tool a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function Check for alignment of moving parts binding of mov ing parts breakage of parts mounting and any other conditions that may affect its operation A guard or other part that is damaged should be ...

Page 5: ...and or serious personal injury Before using battery charger read all instructions and cautionary markings in this manual on battery charger battery and product using battery to prevent misuse of the products and possible injury or damage CAUTION To reduce the risk of electric shock or damage to the charger and battery charge only nickel cadmium rechargeable batteries as specifically designated on ...

Page 6: ...ction min Per Minute Revolutions strokes surface speed orbits etc per minute Wet Conditions Alert Do not expose to rain or use in damp locations Read The Operator s Manual To reduce the risk of injury user must read and understand operator s manual before using this product Eye Protection Always wear safety goggles or safety glasses with side shields and as necessary a full face shield when operat...

Page 7: ...e product to the nearest AUTHORIZED SERVICE CENTER for repair When servic ing use only identical replacement parts WARNING To avoid serious personal injury do not attempt to use this product until you read thoroughly and understand com pletely the operator s manual If you do not understand the warnings and instructions in the operator s manual do not use this product Call Ryobi customer service fo...

Page 8: ...ations DIGITAL Gauge The digital gauge measures and displays air pressure moni tors pressure output and is used to set pressure type HIGH PRESSURE HOSE The high pressure hose can easily inflate high pressure items like motorcycle car and bicycle tires HOSE STORAGE AREA The inflator has twin storage compartments located on each side of the inflator that allow easy storage of both hoses lock on butt...

Page 9: ... side shields when operating inflators Failure to do so could result in objects being thrown into your eyes resulting in possible serious injury WARNING Do not leave items to be inflated unattended while inflator is in use These items can burst and could cause serious injury APPLICATIONS You may use this inflator for the purpose listed below Inflating air mattresses sports balls tires floats and t...

Page 10: ... on until the battery pack is removed from the charger or charger is disconnected from the power supply If both yellow and green LEDs come on this indi cates a deeply discharged or defective battery pack Allow the battery pack to remain in the charger for 15 to 30 minutes When the battery pack reaches normal voltage range the red LED should come on If the red LED does not come on after 30 minutes ...

Page 11: ...epress both sides to release battery pack Remove battery pack from the inflator WARNING Improperly attached hoses or adaptors can become detached under pressure and cause serious injury Possible air leaks can cause faulty pressure readings Make sure all connections are tightly secured END CAP REMOVAL See Figure 5 To access the inflator hoses the end caps must be removed To remove the end caps turn...

Page 12: ...e switch trigger lock on button See Figure 7 The inflator is equipped with a lock on button for continuous inflating over extended periods of time The lock on button is located on top of the handle To lock on Depress the switch trigger Push the lock on button forward Release the switch trigger and the inflator will continue running To release the lock depress the switch trigger again INFLATING WIT...

Page 13: ...edle into sports ball valve and in flate Remove sport ball needle after inflation NOTE Pressure required for most sports balls is too low for accurate reading on gauge The Presta valve adaptor can be used for Presta valve stems as described below See Figure 12 Before inflating a tire with a Presta valve loosen the locking nut on the valve stem to inflate Once inflation is complete tighten the lock...

Page 14: ... been set pressure setting stays in the gauge memory for 120 seconds To recall the previous pressure setting for up to 120 seconds after infla tion press the or button To reset preset pressure press and hold the ON RESET button INFLATING MANUALLY FOR HIGH AND LOW PRESSURE APPLICATIONS Connect either high or low pressure hose to item to be inflated Depress and hold switch trigger until desired pres...

Page 15: ...attery life we suggest the following Remove the battery pack from the charger once it is fully charged and ready for use For battery storage longer than 30 days Store the battery pack where the temperature is below 80 F Store battery packs in a discharged condition BATTERY PACK REMOVAL AND PREPARATION FOR RECYCLING To preserve natural resources please recycle or dispose of batteries properly This ...

Page 16: ...ed below HOW TO ORDER REPAIR PARTS When ordering repair parts always give the following information MODEL NUMBER SERIAL NUMBER Ryobi is a registered trademark of Ryobi Limited used under license WARNING Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or other reproductive harm Some examples of thes...

Reviews: