PRodUct sPecIfIcAtIons

Rated motor power

1500 W

Rated current

6 A

Air outlets

2 pcs, 6.35mm (1/4”) 

Nitto-style quick 

connector (coupler)

Quick connector fitting size

6.35 mm (1/4")

Weight

30.6 kg

Input

220 - 240 V AC, 50 Hz

Power cord length

2.0 m

Air tank capacity

50 L

Free air delivery

120 L/min (4.2 cfm)

Maximum air delivery

190 L/min (6.7 cfm)  

at 0 bar tank pressure

Maximum air pressure

8 bar (115 psi)

Working pressure range

6 - 8 bar (87 - 115 psi)

Pressure gauge

2 pcs, 50.8 mm (2 in.) 

diameter

Maximum rotational shaft 

speed

2,850 rpm

Short-circuit rating  

3 kA

Operating temperature

0 - 45°C

Measured sound pressure 

level (the reference 

number of the noise test 

code: EN ISO 2151:2008)

LpA=70.5 dB(A), 

KpA=2 dB

Measured sound power 

level (the reference 

number of the noise test 

code: EN ISO 2151:2008)

LwA=90.5 dB(A), 

KwA=2 dB

Intended Use

This compressor is designed to supply pressurised air 

only. It must not be used to compress any other gas. It is 

designed to operate air powered tools. The compressor 

should be operated under cover or protected from rain.

AssemBLy

UnPAckIng

This product requires assembly. Carefully remove the 

product and any accessories from the box.

 

 wARnIng

Do not use this product if any parts on the packing 

list are already assembled to your product when you 

unpack it. Parts on this list are not assembled to the 

product by the manufacturer and require customer 

installation. Use of a product that may have been 

improperly assembled could result in serious personal 

injury.
Inspect the product carefully to make sure no breakage 

or damage occurred during shipping.
Do not discard the packing material until you have 

carefully inspected and satisfactorily operated the 

product.

 

 wARnIng

If any parts are damaged or missing do not operate this 

product until the parts are replaced. Use of this product 

with damaged or missing parts could result in serious 

personal injury.

 

 wARnIng

Do not attempt to modify this product or create 

accessories not recommended for use with this 

product. Any such alteration or modification is misuse 

and  could  result  in  a  hazardous  condition  leading  to 

possible serious personal injury.

 

 wARnIng

Do not connect to power supply until assembly is 

complete. Failure to comply could result in accidental 

starting and possible serious personal injury.

Packing list

 

Air compressor

 

Front handle

 

Bottle of oil

 

Air filter

 

Wheel x 2

 

Rubber foot x 2

 

Bolt x 6

 

Nut x 4

 

Flat washer x 8

 

Wheel axle cover x 2

 

Axle bolt x 2

 

Operator's manual

InstALLIng fRont HAndLe

See figure 3.

1.  Insert both ends of the front handle in handle slots.

2.  Secure both ends with 2 hex bolts each using a hex 

Summary of Contents for Airwave RA-C2550-G

Page 1: ...irect driven air compressor Operator s MANUAL Original instructions RA C2550 Important It is essential you read the instructions in this manual before starting and operating this machine Subject to technical modifications ...

Page 2: ... 9 Regulated pressure gauge 10 Wheel 11 Rubber foot 12 Drain valve 13 Rear handle 14 Handle slot 15 Bolt 16 Flat washer 17 Hex nut 18 Wheel axle cover 19 Axle bolt 20 Oil fill hole cap 21 Sight glass 22 Red dot 23 Quick connect air fitting 24 To close 25 Quick coupler 26 To open 27 Reset button 28 Drain valve knob 29 Ring 30 Air filter housing 31 Air filter 32 Air filter cover 33 Wing nut 34 Drain...

Page 3: ...Fig 2 Fig 4 Fig 6 Fig 5 1 1 11 16 5 15 18 19 10 16 17 17 16 13 12 11 4 5 Fig 3 15 14 ...

Page 4: ...Fig 7 Fig 11 Fig 10 Fig 12 25 23 Fig 8a Fig 8b Fig 9 7 4 24 20 22 23 7 3 9 26 21 ...

Page 5: ...Fig 13 Fig 16 Fig 14 Fig 15 28 27 4 29 16 33 32 31 30 ...

Page 6: ...Fig 17 34 ...

Page 7: ... operation is dusty Protect your hearing Wear hearing protection during extended periods of operation Do not overreach Keep proper footing and balance at all times Remove adjusting keys and wrenches Form habit of checking to see that keys and adjusting wrenches are removed from tool before turning it on Air compressor use and care Do not exceed the pressure rating of any component in the system Pr...

Page 8: ...nimals Take care not to blow dust and dirt towards yourself or others Following this rule will reduce the risk of serious injury Do not use this air compressor to spray chemicals Your lungs can be damaged by inhaling toxic fumes A respirator may be necessary in dusty environments or when spraying paint Do not carry while painting Inspect product cords and hoses periodically and if damaged have the...

Page 9: ... the packing list are already assembled to your product when you unpack it Parts on this list are not assembled to the product by the manufacturer and require customer installation Use of a product that may have been improperly assembled could result in serious personal injury Inspect the product carefully to make sure no breakage or damage occurred during shipping Do not discard the packing mater...

Page 10: ... Using a funnel carefully pour oil into the oil fill hole Fill only with synthetic oil SAE 30 NOTE Avoid using too much oil Ensure that the level of the oil does not exceed the top of the red dot at sight glass 3 Tighten the cap securely into the oil fill hole Replace the oil after the first 10 hours of operation and every 100 hours following the first oil change Refer to the Replacing oil section...

Page 11: ...y the manufacturer of the item being inflated WARNING Always ensure the switch is in the OFF O position and the regulator pressure gauge reads zero before changing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible serious personal injury USING THE AIR COMPRESSOR See figure 10 12 1 Ensure power switch is in the OFF O position and air compressor is unp...

Page 12: ... is stuck and cannot be actuated by the ring do not use the air compressor until the safety valve has been replaced Use of the air compressor in this condition could result in serious personal injury RESET BUTTON See figure 13 When current into the air compressor motor exceeds the specified limit the air compressor will automatically shut off To reset the air compressor 1 Unplug the air compressor...

Page 13: ...nd washer Replacing oil See figure 17 WARNING The hot oil can surface can scald or burn your hands Allow the compressor to cool 15 minutes before removing the drain plug and draining the oil Replace the oil after the first 10 hours of operation and every 100 hours following the first oil change The sight glass indicates the oil level and lets the operator check if oil should be added 1 Place a sui...

Page 14: ...ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as far from the spraying area as possible Keep compressor at least 10 m from the spraying area and all explosive vapours Hot surface To reduce the risk of injury or damage avoid contact with any surface Risk of breathing Air obtained directly from the air compressor should never be used to supply air f...

Page 15: ...auge wire and cord length Shorted or open motor winding Take compressor to service centre Defective check valve or unloader Take compressor to service centre Current limiting protector cuts out repeatedly Low voltage Check with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge w...

Page 16: ...usage Take compressor to service centre Decrease air usage compressor not large enough for tool s requirement Piston rings are worn Replace piston rings air inlet filter is blocked call customer service for assistance Air output lower than normal Broken inlet valves Take compressor to service centre Connections leaking Tighten connections ...

Page 17: ...11 Parts list ...

Page 18: ...Handle sleeve 09 Bolt M5 x 18 29 Nut M8 49 Handle 69 Cushion foot 10 Breather and oil fill plug 30 Capacitor 30μf 50 Bolt M8 x 25 70 Flat washer 8 big 11 Circlips for holes 12 31 Flat washer 5 51 Pressure switch 85 115 psi 71 Bolt M3 x 8 12 Piston pin 32 Spring washer 5 52 Pressure gauge G1 8 180 psi 72 Spring washer 3 13 Piston 33 Hex bolt M5 x 110 53 Bolt G1 4 73 Nut 3 14 Piston ring set 34 Cove...