background image

12

No.

Description

No.

Description

No.

Description

No.

Description

01

Crankcase

21

Valve assembly

41

Bearing 6202

61

Unloading pipe

02

Crank web

22

Head gasket

42

Stator

62

Wheel bolt M10 x 56

03

Hex socket bolt,  

M8 x 22, LH

23

Cylinder head

43

Rotor

63

Wheel 7"

04

Connecting rod

24

Flat washer 8

44

Bearing 6203

64

Flat washer 10

05

Gasket

25

Spring washer 8

45

Oil sealing 40 x 20 x 7

65

Nut M10

06

Crankcase cover

26

Hex bolt M8 x 110

46

Thermal cutout

66

Drain cock

07

Gasket

27

Elbow exhaust

47

Bolt M8 x 30

67

Tank

08

Oil glass

28

Air filter assembly

48

Plug and cord assembly

68

Handle sleeve

09

Bolt M5 x 18

29

Nut M8

49

Handle

69

Cushion foot

10

Breather and oil fill plug

30

Capacitor 30μf

50

Bolt M8 x 25

70

Flat washer 8 big

11

Circlips for holes 12

31

Flat washer 5

51

Pressure switch  

85-115 psi

71

Bolt M3 x 8

12

Piston pin

32

Spring washer 5

52

Pressure gauge G1/8, 

180 psi

72

Spring washer 3

13

Piston

33

Hex bolt M5 x 110

53

Bolt G1/4

73

Nut 3

14

Piston ring set

34

Cover

54

Quick connect valve

74

15

Bolt M12 x 16

35

Hex socket bolt 

M6 x 10

55

BM regulator

75

16

Gasket, cylinder lower

36

Bolt M5 x 16

56

Safety valve

76

17

Cylinder

37

Screw ST4.2 x 12

57

Rubber washer

77

18

Round pin,  

Diameter 3 x 6 mm 

38

Shaft circlip 14

58

Exhaust pipe

78

19

Valve reed

39

Fan

59

Quick connect valve

79

20

Gasket, cylinder upper

40

Motor end cap

60

Unloading nut

80

Summary of Contents for Airwave RA-C2550-G

Page 1: ...irect driven air compressor Operator s MANUAL Original instructions RA C2550 Important It is essential you read the instructions in this manual before starting and operating this machine Subject to technical modifications ...

Page 2: ... 9 Regulated pressure gauge 10 Wheel 11 Rubber foot 12 Drain valve 13 Rear handle 14 Handle slot 15 Bolt 16 Flat washer 17 Hex nut 18 Wheel axle cover 19 Axle bolt 20 Oil fill hole cap 21 Sight glass 22 Red dot 23 Quick connect air fitting 24 To close 25 Quick coupler 26 To open 27 Reset button 28 Drain valve knob 29 Ring 30 Air filter housing 31 Air filter 32 Air filter cover 33 Wing nut 34 Drain...

Page 3: ...Fig 2 Fig 4 Fig 6 Fig 5 1 1 11 16 5 15 18 19 10 16 17 17 16 13 12 11 4 5 Fig 3 15 14 ...

Page 4: ...Fig 7 Fig 11 Fig 10 Fig 12 25 23 Fig 8a Fig 8b Fig 9 7 4 24 20 22 23 7 3 9 26 21 ...

Page 5: ...Fig 13 Fig 16 Fig 14 Fig 15 28 27 4 29 16 33 32 31 30 ...

Page 6: ...Fig 17 34 ...

Page 7: ... operation is dusty Protect your hearing Wear hearing protection during extended periods of operation Do not overreach Keep proper footing and balance at all times Remove adjusting keys and wrenches Form habit of checking to see that keys and adjusting wrenches are removed from tool before turning it on Air compressor use and care Do not exceed the pressure rating of any component in the system Pr...

Page 8: ...nimals Take care not to blow dust and dirt towards yourself or others Following this rule will reduce the risk of serious injury Do not use this air compressor to spray chemicals Your lungs can be damaged by inhaling toxic fumes A respirator may be necessary in dusty environments or when spraying paint Do not carry while painting Inspect product cords and hoses periodically and if damaged have the...

Page 9: ... the packing list are already assembled to your product when you unpack it Parts on this list are not assembled to the product by the manufacturer and require customer installation Use of a product that may have been improperly assembled could result in serious personal injury Inspect the product carefully to make sure no breakage or damage occurred during shipping Do not discard the packing mater...

Page 10: ... Using a funnel carefully pour oil into the oil fill hole Fill only with synthetic oil SAE 30 NOTE Avoid using too much oil Ensure that the level of the oil does not exceed the top of the red dot at sight glass 3 Tighten the cap securely into the oil fill hole Replace the oil after the first 10 hours of operation and every 100 hours following the first oil change Refer to the Replacing oil section...

Page 11: ...y the manufacturer of the item being inflated WARNING Always ensure the switch is in the OFF O position and the regulator pressure gauge reads zero before changing air tools or disconnecting the hose from the air outlet Failure to do so could result in possible serious personal injury USING THE AIR COMPRESSOR See figure 10 12 1 Ensure power switch is in the OFF O position and air compressor is unp...

Page 12: ... is stuck and cannot be actuated by the ring do not use the air compressor until the safety valve has been replaced Use of the air compressor in this condition could result in serious personal injury RESET BUTTON See figure 13 When current into the air compressor motor exceeds the specified limit the air compressor will automatically shut off To reset the air compressor 1 Unplug the air compressor...

Page 13: ...nd washer Replacing oil See figure 17 WARNING The hot oil can surface can scald or burn your hands Allow the compressor to cool 15 minutes before removing the drain plug and draining the oil Replace the oil after the first 10 hours of operation and every 100 hours following the first oil change The sight glass indicates the oil level and lets the operator check if oil should be added 1 Place a sui...

Page 14: ...ventilated Do not smoke while spraying or spray where spark or flame is present Keep compressors as far from the spraying area as possible Keep compressor at least 10 m from the spraying area and all explosive vapours Hot surface To reduce the risk of injury or damage avoid contact with any surface Risk of breathing Air obtained directly from the air compressor should never be used to supply air f...

Page 15: ...auge wire and cord length Shorted or open motor winding Take compressor to service centre Defective check valve or unloader Take compressor to service centre Current limiting protector cuts out repeatedly Low voltage Check with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge w...

Page 16: ...usage Take compressor to service centre Decrease air usage compressor not large enough for tool s requirement Piston rings are worn Replace piston rings air inlet filter is blocked call customer service for assistance Air output lower than normal Broken inlet valves Take compressor to service centre Connections leaking Tighten connections ...

Page 17: ...11 Parts list ...

Page 18: ...Handle sleeve 09 Bolt M5 x 18 29 Nut M8 49 Handle 69 Cushion foot 10 Breather and oil fill plug 30 Capacitor 30μf 50 Bolt M8 x 25 70 Flat washer 8 big 11 Circlips for holes 12 31 Flat washer 5 51 Pressure switch 85 115 psi 71 Bolt M3 x 8 12 Piston pin 32 Spring washer 5 52 Pressure gauge G1 8 180 psi 72 Spring washer 3 13 Piston 33 Hex bolt M5 x 110 53 Bolt G1 4 73 Nut 3 14 Piston ring set 34 Cove...

Page 19: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand ...

Reviews: