background image

OPERATOR’S MANUAL

FH3OL195N

3 GALLON PORTABLE AIR COMPRESSOR

FH3OL195N OM Ver. 07/19

CUSTOMER SERVICE

1-866-242-4298

Thank you for buying a FINI product.

Your air compressor has been engineered and manufactured to FINI’s high standard for dependability, ease of operation, 
and operator safety. When properly cared for, it will give you years of rugged, trouble-free performance.

  WARNING:

To reduce the risk of injury, the user must read and understand the operator’s manual before using this product.

SAVE THIS MANUAL FOR FUTURE REFERENCE

www.finiusa.com

Summary of Contents for FH3OL195N

Page 1: ... has been engineered and manufactured to FINI s high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product SAVE THIS MANUAL FOR FUTURE REFERENCE www finiusa com ...

Page 2: ...TURN TO STORE IMPORTANT STOP STOP Compressor Support 1 866 242 4298 Air Compressor will automatically shut off when maximum PSI is reached When the tank pressure drops to the cut in pressure low pressure and the on off switch is in the ON position the unit will automatically restart date for reference DANGER This compressor pump is not equipped and should not be used to supply breathing quality ai...

Page 3: ...ion will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the employer and user must ensure that ...

Page 4: ...r personnel Service or maintenance performed by unqualified personnel may result in a risk of injury GENERAL SAFETY RULES Disconnect the power supply open the drain valve to decompress the tank and allow water to drain and allow the air compressor to become cool to the touch before servicing Turn the pressure regulator knob fully counterclockwise after shutting off the compressor When servicing a ...

Page 5: ...ES Arcing parts Use spray gun hose at least 25 feet long and keep the compressor motor at least 20 feet away from explosive vapors Always follow all safety rules recommended by the manufacturer of your tool in addition to all safety rules for the air compressor Following these rules will reduce the risk of serious personal injury Never direct a jet of compressed air toward people or animals Take c...

Page 6: ...Risk of Bursting Do not adjust the regulator to result in output pressure greater than the marked maximum pressure of the attachment Do not use at a pressure greater than the rated maximum pressure of this compressor Risk of Fire of Explosion Do not spray flammable liquid in a confined area Spray area must be well ventilated Do not smoke while spraying or spray where spark or flame is present Keep...

Page 7: ...ituation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without Safety Alert Symbol Indicates a situation that may result in property damage WARNING The o...

Page 8: ...isk of electric shock EXTENSION CORDS Use only 3 wire extension cords that have 3 prong grounding plugs and 3 pole receptacles that accept the air compressor s plug When using the air compressor at a considerable distance from the power source use an extension cord heavy enough to carry the current that the compressor will draw An undersized extension cord will cause a drop in line voltage resulti...

Page 9: ...tions Pressure Regulator Knob Regulates the outgoing pressure from the air outlet to the tool It is possible to increase or decrease the pressure at the outlet by adjusting this control knob Pressure Switch Automatically controls the on off cycling of the compressor It stops the compressor when the cut off pressure in the tank is reached and starts the compressor when the air pressure drops below ...

Page 10: ...CFM 90 PSI Duty Cycle S3 50 5 minutes ON and 5 minutes OFF Lubrication Oil Free Gauges 2 0 in diameter Input 120 V 60 Hz AC only 9 Amps Net Weight compressor only 24 3 lbs Fig 2 REGULATOR PRESSURE GAUGE TANK PRESSURE GAUGE HANDLE PRESSURE REGULATOR KNOB QUICK COUPLER SAFETY VALVE RUBBER FOOT TANK MANUAL ON OFF SWITCH DRAIN VALVE ...

Page 11: ... thermal overload protector If the motor overheats for any reason the thermal overload will cut off power thus preventing the motor from being damaged Wait until the motor is cool Motor resets automatically AIR INTAKE FILTER This filter is designed to clean air coming into the pump To ensure the pump continually receives a clean cool dry air supply this filter must always be clean and ventilation ...

Page 12: ...e air compressor becomes overheated If the motor turns OFF repeatedly check for the following possible causes first Low Voltage from the outlet Lack of proper ventilation or outside air or room temperature too high Extension cord too long or wrong gauge wire used To reset the air compressor Turn the air compressor off Unplug the air compressor and allow it to cool for 30 minutes Plug the air compr...

Page 13: ...ise will completely stop the flow of air NOTE Always use the minimum amount of pressure necessary for your application Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently When finished always drain the tank and unplug the unit Never leave the unit plugged in and or running unattended WARNING Check the air tool manual to ensur...

Page 14: ...l moisture has been removed Drain moisture from tank into a suitable container NOTE Condensate is a polluting material and should be disposed of in compliance with local regulations If drain valve is clogged release all air pressure by pulling the safety valve Remove and clean valve then reinstall Close the drain valve by rotating it turn clockwise CHECKING THE SAFETY VALVE See Figure 9 The safety...

Page 15: ...ur using the instructions found in Draining the Tank The safety valve automatically releases air if the air receiver pressure exceeds the preset maximum Check the safety valve before each use following the instructions found in Checking the Safety Valve Inspect the tank yearly for rust pin holes or other imperfections that could cause it to become unsafe Avoid using solvents when cleaning plastic ...

Page 16: ...ssor to a service center The thermal overload protector cuts out repeatedly The voltage from the power supply is low A poorly ventilated room is causing the motor to overheat The gauge wire or the length of extension cord is wrong Check the voltage with a voltmeter Move the compressor to well ventilated area Check for proper gauge wire and cord length The air receiver pressure drops when the compr...

Page 17: ...17 REPLACEMENT PARTS LIST ...

Page 18: ... 4 9038929 FOOT 4 9122451 4 007 9049115 1 008 9412186 1 009 9043664 1 010 9069260 1 011 9415794 1 012 9050671 1 013 9069262 1 014 9083679 1 9069263 1 9142773 2 017 9069261 1 018 9412472 2 019 9064830 1 020 B_AC0774 ISOLATOR 2 021 9063276 1 022 9142572 2 023 9050698 2 024 9045670 9417577 FITTING BARB 90 1 4 1 9065680 1 027 9415375 1 028 9054016 1 029 9104024 4 030 9069035 1 031 9051219 1 032 905215...

Page 19: ...19 REPLACEMENT PARTS LIST ...

Page 20: ...eplacement parts KEY NO CODE DESCRIPTION QTY 001 9417760 1 002 A631040 1 003 A661409 1 004 A661204 1 9415091 1 008 A710100 1 019 9131678 1 028 9054016 1 030 9170113 1 031 9170114 2 041 9416831 1 9140211 1 9038566 FAN 1 A650300 1 9415052 1 078 9040048 PISTON RING 1 9075338 1 ...

Page 21: ...cover normal wear and tear or any malfunction failure or defect resulting from misuse abuse neglect alteration modification or repair by other than a service center authorized to repair FINI branded air compressors Expendable materials such as motor brushes seals etc are not covered by this warranty This warranty does not apply to this compressor used in industrial applications or for rental purpo...

Reviews: