E n e r g y T e c h n o l o g y
Ltd.
11
9.1 gas
conversion
The MICROMAT EC is factory fitted for Natural Gas (G20). However the unit can easily be converted to LPG (G31)
by using the kit supplied (part no. 251588) and following the instructions below.
• Remove cover from boiler
• Open the outlet flange joints at the gas combi valves.
• On the outlet side of the gas combi valve add the Ø 5.7mm LPG jets from the conversion kit.
• On the inlet side of the left hand gas combi valve only, replace the NG jet with the 3.5mm LPG Prejet.
• Re-tighten the flange joint. Do not forget the O-rings.
• Check for Leakage.
• On the MICROMAT EC 45 H/62 H/76 H, when converting to LPG, the front bore on both gas/air mixing
chambers must be closed using the black ø10mm plugs supplied in the conversion kit.
• In addition, with the MICROMAT EC 76H both back bores in both gas/air mixing chamber must be closed
using the Ø15mm plugs supplied in the conversion kit.
Enter the gas type to which the MICROMAT EC is converted on the label next to the type label