AtEX CHECK List
Complete the following check list prior to operation in a potentially hazardous area.
All actions must be completed in accordance with
EX/ATEX 100a
.
Read the user guide to check that the machine/tool has been designed for use in the hazardous
application area you intend to use it in.
*
Hazardous zone
*
Hazardous category
*
Equipment group
*
Temperature class
*
Maximum surface temperatures.
Ensure the machine shows the correct info.
ll Equipment group ll : Group II, Category 2 equipment
2 Equipment Category 2
G gas atmospheres: : Gas Class IIA only
D Dust atmospheres
c Constructional safety
T Max surface temp.: +135
°
C
Ambient range : -20
°
C - +60
°
C
Special conditions for safe use:
· Only to be used by trained personnel.
· shall not be used on paint systems with and aluminium contend greater than 10% of its dry film
thichkness
· shall not be used on light metals such as titanium and magnesium.
· Maximum work pressure of 8 bar.
· the equipment must be properly earthed/grounded before use.
· Only original
Rustibus®
replacement spare parts are to be used.
*
Check the area/surface for potentially explosive oils, acids, gases, vapors or radiation.
before operation the area should have be prepared properly for surface preparation to be carried out.
Free from contaminants.
*
Check the ambient temperature of the site /surface and the ability to maintain the proper ambient
temperature.
Ambient range:
*
Normal conditions: 1
°
C to 121
°
C
*
Hazardous conditions: 1
°
C to 60
°
C
EX II 2 GD c IIA T135
°
C
-20
°
C
<
Ta
<
+60
°
C
DNV 11 ATEX 95218X
type
No.
Weight
Year
X400
....................
24kg/53lbs
201....
Dalseide shipping services As
MADE iN NORWAY
ii 2 GD c iiA t135°C
-20 °C < ta < +60°C
DNV 11 AtEX 95218X
PAtENtED
Genuine Rustibus® parts only!
Machine may vary from pictures
Summary of Contents for 040-X3000
Page 1: ...040 X3000 Rustibus X400 AIR Ex Certified OPERATION MANUAL ...
Page 29: ......
Page 30: ......
Page 31: ......