before you begin.
Step 1: VERIFY THE COMPLETENESS OF YOUR RUSTIBUS® MACHINE.
•
Check that all components are attached properly and in a proper / safe working order.
(Check that there are no loose wires, guards or parts on the machine)
Step 2: ASSOCIATED EQUIPMENT.
•
Ensure that you have available required Air Pressure & volume.
(2,4 m³/min (85 CFM ) / 7-8 bar (101-116psi))
•
Ensure that you have available Air tool oil to fill the Lubricator to the required level.
Step 3: BEFORE COMMENCING THE OPERATION.
•
Locate the section to be cleaned / de-scaled and determine if the area needs to be cleaned. Excessive
grease, dirt and other hazardous material should be cleaned from the surface area before
operation of the
Rustibus®
machine.
•
Check the site to ensure the air motor of the machine/tool will be adequately ventilated and that
there is no external heat input (e.g. couplings). The cooling air may not exceed 60
°
C
• Check that the air motor of the machine/tool is not damaged. And that the machine /tool itself is
not damaged in anyway that may effect its EX/ATEX compliance
• Confirm the correct air pressure before connecting hose supply.
• Check oil level container and fill with air tool oil as required (Only fill to 75%)
• The Chain drum is rotating at high RPM, show outmost care when connecting Air hose and when
operating machine.
ALWAYS THINK SAFETY FIRST!
• Connect your machine to its power source.
• Make sure the air hose is properly connected and safely located for your operation. Apply safety wire
on hose.
•
ALWAYS
lift up machine (push down the handle) in order for the chain drum to rotate freely when
starting the machine.
• Start and Stop the machine and check that rotation is correct according to marking on machine.
Step 4: OPERATION OF RUSTIBUS® MACHINE.
• For the best results from your
Rustibus®
machine you should run the machine forward and backward
over the area until appropriate result is achieved
• Do not run the machine over sharp edges, but along them. Your machine will last longer if operated
with care.
•
Operate the machine for approximately 2 hours at the maximum desired load. Measure the surface
temperatures of the motor casting opposite the ports / or above the main port. Re Check with
Pre-Start checks.
Genuine Rustibus® parts only!