RUSH PAR 2 CT Zoom™ User Manual
11
4. Working from a stable platform, hang the fixture with its clamp on the
truss and fasten the clamp securely.
5. Secure the fixture with a safety cable as directed below.
Securing with a safety cable
Secure the fixture with a safety cable (or other
secondary attachment) that is approved for the weight
of the fixture so that the safety cable will hold the
fixture if a primary attachment fails.
Loop the cable through one of the safety cable
attachment points on the fixture (see arrows in
illustration on right) and around a secure anchoring
point.
AC power
Read ‘Safety information’ on page 4 before connecting the
fixture to AC mains power.
Warning! The mains power input cable supplied with the
fixture is rated 6 A and can supply only one fixture with
mains power. Do not connect any device to the fixture’s
MAINS OUT power throughput socket when using this
input cable. If you want to connect other fixtures to the
MAINS OUT socket, see ‘Linking fixtures to power in a
chain’ on page 12.
For protection from electric shock, the fixture must be
grounded (earthed). The power distribution circuit must be
equipped with a fuse or circuit breaker and ground-fault (earth-
fault) protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixture can easily be disconnected from
power.
Do not insert or remove live Neutrik PowerCon connectors to apply or cut
power, as this may cause arcing at the terminals that will damage the
connectors.