RUSH PAR 2 CT Zoom™ User Manual 

11 

4.  Working from a stable platform, hang the fixture with its clamp on the 

truss and fasten the clamp securely. 

5.  Secure the fixture with a safety cable as directed below. 

Securing with a safety cable 

Secure the fixture with a safety cable (or other 
secondary attachment) that is approved for the weight 
of the fixture so that the safety cable will hold the 
fixture if a primary attachment fails. 

Loop the cable through one of the safety cable 
attachment points on the fixture (see arrows in 
illustration on right) and around a secure anchoring 
point. 

 

AC power 

 

 

Read ‘Safety information’ on page 4 before connecting the 
fixture to AC mains power.  

Warning! The mains power input cable supplied with the 
fixture is rated 6 A and can supply only one fixture with 
mains power. Do not connect any device to the fixture’s 
MAINS OUT power throughput socket when using this 
input cable. If you want to connect other fixtures to the 
MAINS OUT socket, see ‘Linking fixtures to power in a 
chain’ on page 12. 

For protection from electric shock, the fixture must be 
grounded (earthed). The power distribution circuit must be 
equipped with a fuse or circuit breaker and ground-fault (earth-
fault) protection.  

Socket outlets or external power switches used to supply the 
fixture with power must be located near the fixture and easily 
accessible so that the fixture can easily be disconnected from 
power. 

Do not insert or remove live Neutrik PowerCon connectors to apply or cut 
power, as this may cause arcing at the terminals that will damage the 
connectors.  

Summary of Contents for PAR 2 CT Zoom

Page 1: ...PAR 2 CT Zoom User Manual...

Page 2: ...use of inability to use or reliance on the information contained in this manual The RUSH logo the RUSH name the Martin logo the Martin name and all other trademarks in this document pertaining to ser...

Page 3: ...rol data link 14 Tips for reliable data transmission 15 Connecting the DMX data link 15 Fixture setup 15 Using the control menus 15 DMX addressing 16 Dimming curves 16 Blackout or Hold if DMX signal s...

Page 4: ...he beam Do not view the light output with optical instruments or any device that may concentrate the beam This lighting fixture is for professional use only and must be installed by a qualified techni...

Page 5: ...ure that the fixture is electrically connected to ground earth Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault p...

Page 6: ...input and throughput cables that are 16 A rated and temperature rated to suit the application In the USA and Canada the cables must be UL listed type SJT or equivalent In the EU the cables must be ty...

Page 7: ...y Do not stare directly into the product s light output Do not look at the light output with magnifiers telescopes binoculars or similar optical instruments that may concentrate the light output Ensur...

Page 8: ...and must be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories Check that all external covers and rigging hardware are securely fasten...

Page 9: ...ixture 2 Unpack and ensure that there is no transportation damage before using the fixture Never attempt to operate a damaged fixture 3 If the fixture is not going to be hard wired to an AC mains powe...

Page 10: ...that the surface can support at least 10 times the weight of all fixtures and equipment to be installed on it Fasten the fixture securely If you install the fixture in a location where it may cause in...

Page 11: ...The mains power input cable supplied with the fixture is rated 6 A and can supply only one fixture with mains power Do not connect any device to the fixture s MAINS OUT power throughput socket when u...

Page 12: ...power cable as shown in this table Earth Ground or Neutral or N Live or L US system Green White Black EU system Yellow green Blue Brown The fixture has an auto ranging power supply that accepts AC ma...

Page 13: ...resent 3 Control buttons MENU Activate the menus or Return to the previous level of the menu structure or Press and hold to exit the menus DOWN Scroll down through a menu UP Scroll up through a menu E...

Page 14: ...he fixture has 5 pin XLR connectors for DMX data input and output The number of fixtures that you can connect in a daisy chain is limited by the number of DMX channels required by the fixtures in rela...

Page 15: ...reflect and cause interference If a splitter is used terminate each branch of the link Connecting the DMX data link To connect the fixture to data 1 Connect the DMX data output from the controller to...

Page 16: ...ol and identical fixture behavior give fixtures the same DMX address To set the fixture s DMX address 1 In the fixture s control panel use the UP and DOWN buttons to select DMX ADDRESS and press ENTER...

Page 17: ...HOLD the fixture will continue to show the effect that it is displaying at the time 3 Press ENTER to confirm your choice or press MENU to exit without making a change Display panel backlight sleep mod...

Page 18: ...rm your selection 3 Use the DOWN and UP buttons to change the value 000 255 This will be the equivalent of sending this DMX value to the selected effect 4 Press ENTER to confirm your selection and act...

Page 19: ...o restore DMX operation exit the MANUAL TEST menu on the control panel Fixture information Fixture temperature readout To check the onboard temperature of the fixture 1 Select TEMP and press ENTER The...

Page 20: ...ture control White color temperature can be controlled by mixing warm white and cold white LEDs Electronic dimming Overall intensity can be adjusted 0 100 using electronic dimming Shutter effect The e...

Page 21: ...the fixture Environmental factors that may result in a need for frequent cleaning include Use of smoke or fog machines High airflow rates near air conditioning vents for example Presence of cigarette...

Page 22: ...to cool for at least 15 minutes 2 Use a large flat bladed screwdriver to unscrew the cap of the fuseholder 3 Replace the fuse with one of the same type and rating only 4 Reinstall the fuseholder cap b...

Page 23: ...slow fast 132 139 Open 140 181 Pulse fast close slow open 182 189 Open 190 231 Pulse fast open slow close 232 239 Open 240 247 Strobe random 248 255 Open 4 0 255 Warm White 0 100 Fade 255 5 0 255 Cold...

Page 24: ...erse square law Mode 4 S curve DMX State Blackout Set fixture behavior if DMX signal stops blackout or hold current effect Hold Backlight Off Automatically turn off display backlight when not in use O...

Page 25: ...MX link fault Damaged step motor or cable connection See next section Contact your RUSH by Martin authorized distributor or service center for assistance Fixture does not respond to DMX control Incorr...

Page 26: ...riable speed and action random strobe Electronic shutter effect Instant open and blackout Zoom Motorized Control and Programming Control options DMX single standalone scene DMX channels 7 DMX address...

Page 27: ...cal power consumption 152 W Fuse T 6 3 A Power supply unit Auto ranging electronic switch mode Maximum power and current 120 V 60 Hz 1 25 A 151 W PF 0 993 230 V 50 Hz 0 66 A 148 W PF 0 961 Measurement...

Page 28: ...m 7 4 ft P N 11541510 Power relay cable 14 AWG SJT 1 5 mm2 H05VV F with PowerCon connectors 3 25 m 10 7 ft P N 11541511 Power connectors Neutrik PowerCon NAC3FCA power input connector cable mount blu...

Page 29: ...is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of RUSH by Martin products Photobiological Safety Warning The label shown below is displayed o...