Construction
Color ...................................................................................................... Black
Housing .......................................................................................... Aluminum
Protection rating ..................................................................................... IP 20
Installation
Mounting points .......................... Adjustable bracket, surface or truss mount
Location ....................................................................................... Dry location
Orientation ................................................................................................ Any
Minimum distance to illuminated surfaces .................................. 0.2 m (8 in.)
Minimum distance to combustible material ................................. 0.1 m (4 in.)
Connections
AC power input .................................................................. Neutrik PowerCon
AC power throughput ........................................................ Neutrik PowerCon
DMX data in/out .................................................................. 5-pin locking XLR
Electrical
AC power ......................................................... 100-240 V nominal, 50/60 Hz
Typical power consumption .................................................................. 152 W
Fuse ....................................................................................................T 6.3 A
Power supply unit ................................. Auto-ranging electronic switch mode
Maximum power and current
120 V, 60 Hz ............................................................1.25 A, 151 W, PF 0.993
230 V, 50 Hz ............................................................0.66 A, 148 W, PF 0.961
Measurements made at nominal voltage with all LEDs at full intensity.
Allow for a deviation of +/- 10%.
Thermal
Cooling ................................... Forced air (temperature regulated, low noise)
Maximum ambient temperature (Ta max.) .............................. 40° C (104° F)
Minimum ambient temperature (Ta min) ...................................... 0°C (32° F)
Total heat dissipation* ................................................................. 520 BTU/hr.
*Calculated, +/- 10%, at full intensity.
Approvals
EU safety .................. EN 60598-2-17 (EN 60598-1), EN 62471, EN 62493
EU EMC .............................................. EN 55015, EN 55032, EN 55103-2,
......................................... EN 61000-3-2, EN 61000-3-3, EN 61547
US safety ........................................................................................ UL 1573
US EMC ..................................................................... FCC Part 15 Class A