Main Support no.: +370 5 2045030
Polish Support no.: +48 22 2092532
Ukrainian Support no.: +380 947 107319
5
www.ruptela.com
The device must be firmly fastened in a predefined location. The predefined location is described
in the mounting instructions.
The configuration must be performed using a 2
nd
safety class computer (with an autonomic
power supply).
Make sure that the device is installed in a location where it will not be subjected to harsh
environmental conditions for extended time periods.
Any installation and/or handling during a lightning storm is prohibited.
Caution! If an incorrect type of battery is used for replacement, there is a high explosion risk.
Dispose of used batteries according to the environmental requirements.
For configuration use cables that were purchased from Ruptela. Ruptela is not responsible for
any harm or damage caused, while using wrong cables for the computer
↔
device connection.
Attention! Do not connect the wires marked red (power supply) and black (chassis) to the wrong
battery poles. The device has reverse polarity protection, however if connected incorrectly, the
device will not work.
To disconnect the device from the power supply, you need to disconnect the 12 Pin connector
from the device or disconnect the wires from the vehicle
’
s power supply.
This crossed-out wheelie bin symbol means that waste equipment should not be disposed of
with your other household waste. The product must be taken to separate collection points at
the product
’
s end-of life.
Please follow these ratings to avoid environmental or electrical damage:
FM-Eco4 light S FM-Eco4 light+ S
FM-Eco4+ S
FM-Eco4+ E S
Environmental specifications
Temperature
Operating:
-
30 to +60 °C
Storage:
-
40 to +65 °C
Operating:
-
20 to +60 °C
Battery charging:
0 to +45 °C
Battery discharging:
-
20 to +60 °C
Storage:
-
20 to +60 °C
Electrical specifications
Power supply range
6 ÷
31.5 V DC
Power supply voltage 6/12/24 V DC
Maximum current
rating
400 mA @ 6 V DC 500 mA @ 6 V DC
Internal battery
–
LiPo 3.7 V 190 mAh
Internal fuse rating
3 A
External fuse rating
2 A
To avoid mechanical damage, it is advised to transport the FM device in an impact-proof package.
Before connecting the wires of the 12 Pin cable to the vehicle, it is recommended to ensure that the
cross-sectional area of the wire mounting is at least 0.75 mm
2
. To correctly dismount the device from
the vehicle, first of all disconnect the power supply wires. Only then other plugs or wires can be
disconnected.
The device is intended to be installed in a restricted access location, which is not accessible for the
driver.