8
INFORMATOIN NOISE / MEAN ACCELERATION VALUE
The tools are suppressed in accordance for the prevention and
elimination of radio disturbances measured in accordance with
standard:
UNI EN ISO 15744 - EN ISO 28927-3; EN 28662-1
ROC50-ROC75
SOUND PRESSURE LEVEL dB(A)
80,6
SOUND POWER LEVEL dB(A)
91,6
UNCERTAINTY K
3
TE23
SOUND PRESSURE LEVEL dB(A)
83
SOUND POWER LEVEL dB(A)
94
UNCERTAINTY K
3
ANP125
SOUND PRESSURE LEVEL dB(A)
88
SOUND POWER LEVELdB(A)
99
UNCERTAINTY K
3
TE23
3 AXIS VIBRATION LEVELm/s2
1,07
UNCERTAINTY K
0,60
ROC50-ROC75
3 AXIS VIBRATION LEVEL m/s2
1,60
UNCERTAINTY K
0,65
ANP125
3 AXIS VIBRATION LEVEL m/s2
1,55
UNCERTAINTY K
0,64
Use ear protection!
Displayed emission values are comparative and are to be
employed for a provisional assessment of the operator’s risk
exposure during the work period. Appropriate evaluation of
work period must also include tool’s idle and stop periods.
These emission values represent the tool’s main applications.
If the tool is used for other applications, with other accessories,
or if it does not undergo regular maintenance, emission values
can significantly increase during operations.
Danger! The indicate measurements refer to
new power tools. Daily usa causes the noise and
vibration values to change.
MAINTENANCE
All maintenance operations are carried out with the tool
disconnected from the compressed air supply. At the end of
each work session, or when required, remove anydust from
the body of the tool using a jet of compressed air.
Lubricate the machine regularly (every 50 hours of operation)
by inserting 2/3 drops of specific oil (synthetic oil without
silicone, ISO 32) into the compressed air connection, keeping
the device in a vertical position, with the connection facing
upwards. After this operation, connect the machine to the
power supply and set it in motion for a few seconds. Lubricate
the machine asdescribed above before storing it for long
periods of inactivity. All damages deriving from incorrect or
inadequate lubrication are excluded from the warranty.
No other maintenance operations must be undertaken by
the user.
Maintenance and cleaning of the inner parts, must be carried
out only by an authorized customer-service workshop.
DISPOSAL
At the end of its useful life, the product must not be released
into the environment or thrown away as domestic waste, but
must be disposed of at authorised recycling centres (contact
the relevant local authorities for a list of places where the
product may be disposed of according to the law). Disposing
of the product correctly contributes to protecting human health
and safeguarding the environment. Any illegitimate disposal of
the product will be punishable by law.
CONFORMITY DECLARATION
We declare on our responsibility that the represented
vacuum for industrial use is in conformity with the Essential
Requirements of Safety of the following Directive:
2006/42/CE.
The tests have been carried out in accordance with the
European Harmonised
UNI EN ISO 11148; UNI EN ISO
15744; ISO 28927.
RUPES S.p.A.
THE PRESIDENT
G. Valentini