If you need to reset the system only, ensure that there is no installation package on the SD card or USB flash disk.
Alternatively, simply press the FUNC button without inserting any SD card or USB flash disk. For detailed
operations, see the
RGOS Configuration Guide
of the RSR30-X router.
1.2 Service Modules
Service modules are not supported.
1.3 Power Supply Modules
There are two available power supply modules: M5000E-AC60 and PD240I.
1.3.1 M5000E-AC60
Product Image
Figure 1-3 Appearance of Two M5000E-AC60 Power Supply Modules
Indicators
Indicator
Description
Indicator on the panel
Green: Power output is normal.
Red: Power output is abnormal.
Off: There is NO power output due to faulty power supply module or no inserted cable.
Specifications
Table 1-4 Technical Specifications of the
M5000E-AC60 Module
Module Model
RG-M5000E-AC60
Rated Voltage Range
100VAC-240VAC, 50-60Hz
Max Voltage Range
90VAC~264VAC, 50-60Hz
Power
60W
Hot Swapping
Supported
Power Redundancy
Supporting 1+1 power redundancy
Overvoltage
Protection
13.4VAC-16VAC
Overcurrent Protection
6A-12A
Power Supply Mix
Not supported
Power Cord
Requirement
10A power cord