CSU/DSU or other DCE device 

Configuration terminal, which may be a client or a PC with hyper terminal installed 

Router modules 

Power sockets 

 

Some tools are customer supplied. 

 

3  Router Installation 

3.1  Procedure for Installing Router 

Please follow the following procedure to install the router to ensure the smooth installation and avoid any damage to the 

unit: 

 

Summary of Contents for RSR30-X-SPU10

Page 1: ...RSR30 X Series Router Hardware Installation and Reference Guide...

Page 2: ...m or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any...

Page 3: ...http community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes networ...

Page 4: ...dustries such as telecommunications private network ISP finance tax public security and railways as well as middle and large sized enterprises The RSR30 X has the following features Reliability advanc...

Page 5: ...rt both service modules and power supplies support hot swapping Power Redundancy Support Memory DDR 2 GB FLASH 512 MB I O Interface Ethernet interface Nine GE ports GE 0 0 0 0 0 8 that support auto ne...

Page 6: ...or is not properly inserted or the module can be unplugged Blinking green The module is initializing Solid green Initialization is complete and the module is operational SD SD card status indicator O...

Page 7: ...d either is available at a time The port for mini USB is the mini USB B connector and only the 5 pin mini B connector or compatible connector cable can be used To use the U Console port install the de...

Page 8: ...ly when no SD card is inserted or no installation package is available on the SD cards If no installation package is available on the inserted SD card and USB flash disk the system resets and but does...

Page 9: ...Figure 1 3 Appearance of Two M5000E AC60 Power Supply Modules Indicators Indicator Description Indicator on the panel Green Power output is normal Red Power output is abnormal Off There is NO power o...

Page 10: ...ecifications of the M5000E AC60 Module Module Model RG PD240I Rated Voltage Range 36VDC 72VDC Power 60W Hot Swapping Supported Power Redundancy Supporting 1 1 power redundancy Overvoltage Protection 1...

Page 11: ...e UPS to prevent power failure and other interferences 2 1 1 Electrical Safety Please observe local regulations and specifications when performing electrical operations Relevant operators must be qual...

Page 12: ...perature and humidity in the equipment room If the humidity is high for a long time mechanical changes like faulty insulation or even electrical leakage may occur If the relative humidity is low the i...

Page 13: ...d resist interference Please carefully check the grounding conditions on the installation site according to the grounding requirements and perform grounding properly as needed Safety Grounding The equ...

Page 14: ...ng protection 2 2 8 Checking Installation Location Whether the router is installed in a cabinet or placed on a workbench make sure There is enough room at the inlet wind gap and the vent of the router...

Page 15: ...PC with hyper terminal installed Router modules Power sockets Some tools are customer supplied 3 Router Installation 3 1 Procedure for Installing Router Please follow the following procedure to instal...

Page 16: ...routers The module to be installed is the M5000E AC60 power module 1 Place the router in such a way that you face the rear panel of its host 2 Remove the empty barrier on the slot where the power mod...

Page 17: ...he power supply socket should be installed near the device for convenient plugging 3 4 Installing the Grounding Cable and the Power Cable Ruijie RSR30 X series routers support the following AC power s...

Page 18: ...ct one end of the supplied power cable to the socket on the rear panel of the cabinet and another to the AC power socket 2 Turn the router to power on position 3 Check the power indicator on the front...

Page 19: ...terminal block in the chassis Figure 3 2 PD240I Power Plug Installation The installation procedures are as follows 1 Take the DC power module PD240I and cables from the carton and insert the DC power...

Page 20: ...r cables are correctly installed before you power the device on Before installing the power module ensure that the power switch is off 3 6 2 Removing the DC Power Module Note This section applies to t...

Page 21: ...the same port and either is available at a time The 4 pin mini B USB may be easily confused with the 5 pin mini B USB Only the 5 pin mini B connector can be used 4 Router Startup and Configuration 4 1...

Page 22: ...at you may cut power supply in time in case of accident 4 1 2 2 Powering on Router Turn the router to the power on position 4 1 2 3 Check after Powering on After powering on the router please check If...

Page 23: ...5 MTD_NAND_FOUND 1 NAND chips chip size 536870912 detectedCopyright c 1998 2014s by Ruijie Networks All Rights Reserved Neither Decompiling Nor Reverse Engineering Shall Be Allowed Jan 1 00 02 29 SYS...

Page 24: ...er 4 during the start will appear on the terminal If a fault occurs nothing or illegible characters will appear If no information appears on the terminal display please check If the power system is wo...

Page 25: ...pasted on the curved position or other positions that may affect the installation The text on a label must be in the format from left to right or from up to down as shown in Figure 6 1 Details are as...

Page 26: ...the two ports connected by the cable Write the content based on the onsite environment 1 Write information about the local end in Area 1 2 Write information about the peer end in Area 2 3 Area 3 will...