RG-SS6510
-
4C Series Switch Hardware Installation and Reference Guide
Product Overview
- 7 -
Solid blue
Device location is enabled.
MGMT port indicator
MGMT
Off
The port is not connected.
Green
The port is connected at 1000Mbps.
Yellow
The port is connected at 10/100Mbps.
Blinking
The port is transmitting or receiving data.
Power Supply
The RG-S6510-4C series switch supports power supply the PA800I-F. The smart power supply module supports power
management, and the host can read input power, input current, and temperature in real time. The power supply module
supports hot swapping.
The RG-S6510-4C series switch supports 1+1 power supply redundancy. To improve the stability and reliability of
the entire system, it is recommended to configure 1+1 power supply redundancy. When the two power supply
modules work normally, the switch is in the status of current sharing.
It requires at least one power supply module to work normally. Install a blank panel to the empty slot to prevent
dust from entering the switch.
Heat Dissipation
The working temperature of the RG-S6510-4C switch is 0°C to 40°C (32°F to 104°F), and the heat dissipation design
needs to ensure the stability, safety and maintainability in such environment. The RG-S6510-4C series switch adopts
fan ventilation and forced convection to ensure the device can work normally in specified environment. Dust the device
every three months to avoid blocking the ventilation openings.
The RG-S6510-4C supports M6500-FAN-F and provides fan speed regulation, fan failure warning, and fan hot
swapping.
Figure 1-5 Ventilation and Heat Dissipation of the RG-S6510-4C
Maintain a minimum of 20 cm clearance around the device for ventilation.
It requires at least two fan modules to work normally. Install a blank panel to the empty slot to prevent dust from
entering the switch.