If a slot is not inserted with a supervisor module, or service module, please cover the slot with a filler panel for heat dissipation.
4.11 Connecting the Power Cord
Connect the power cord to the location as required according to the identification on the power module panel, including RG-PA1600I,
RG-PA600I,
RG-PA3000I-PL and RG-PA1600I-PL
.
Make sure the socket is powered off before the power cord is connected.
1)
Insert the AC power plug into the power module socket.
2)
Take out the spring clip.
3)
Install the spring clip on the front panel of the power module.
4)
Fasten the spring clip to the power cord.
5)
Connect the other end of the power cord to an external power socket.
Figure 4-15 Connecting Power Cord
Please use the 3-pin power cord. The cross-sectional area of each pin is 1.5 mm
2
or 14 AWG minimum.
16A and 10A power cords are available for the RG-S7808C AC power supply. Adopt the proper socket and verify the AC power
supply capacity in the machine room.