background image

 

Tumbler MKR 600 

and indication must remain on the display. - Now close the lid 
fully. - When reaching the 

“Closed”

 end position the lid and in-

dication must remain on the display. If the lid or indication on 
the display do not remain, the machine must be shut down 
immediately! Error messages of the control system must be 
heeded! 

 

!!! To shut down the machine the main switch must be turned to 

“0”

 - 

OFF" and the power plug pulled from the outlet! The machine must be 
secured against further use! 
 
!!! The supervisor must arrange for the repair of the non-functional 
safety device by a Rühle service technician. Until the corresponding 
parts have been repaired, the supervisor must ensure that the ma-
chine or parts of the machine are under no circumstances put into op-
eration! 
 
!!! The cleaning personnel must observe the work procedures from the 

“Cleaning”

 work instructions prepared by the supervisor. 

 
!!! The maintenance personnel may only carry out work specified as 

“Regular care”

, unless any other authorisation has been issued in 

writing by the manufacturer of the machine. The maintenance per-
sonnel must observe the work procedures from the 

“Maintenance”

 

work instructions prepared by the supervisor. 
The power plug must be disconnected for maintenance work! 
 
!!! The machine may not be modified. 
 
!!! Only Rühle spare parts and accessories may be used. 
 
!!! The operating instructions as well as all other technical documents 
included must be supplied completely when reselling the machine. 
 

Summary of Contents for MKR 600

Page 1: ...ebensmitteltechnik Translation of the original instructions Tumbler Type MKR 600 R hle GmbH Beim Signauer Schachen 10 D 79865 Grafenhausen Tel 49 7748 523 11 Fax 49 7748 523 8511 www original ruehle d...

Page 2: ...Operating instructions 9 4 Cleaning instructions 12 4 1 Safety instructions 12 4 2 Cleaning agents and disinfectants 13 4 3 Cleaning procedure 13 5 Service Care maintenance repair 14 5 1 Regular care...

Page 3: ...e mains during this process Refrigeration installer These work activities may be carried out only by a re frigeration installer Disregard may result in injuries Warning of hot surface Warning of suspe...

Page 4: ...antling Wear eye protection Use light breathing mask The operator must operate the machine according to the intended use and strictly observe all points listed in the Operation work in structions prep...

Page 5: ...e been repaired the supervisor must ensure that the ma chine or parts of the machine are under no circumstances put into op eration The cleaning personnel must observe the work procedures from the Cle...

Page 6: ...cooling unit and cooling system may only be carried out by a refrigeration installer All life cycles phases Staying under the lifting aid standard trolley support is strictly prohibited and the stand...

Page 7: ...as is prohib ited Handling processing products and materials not belonging to food products is prohibited The lifting aid may be used only for the standard trolleys pro vided and must not be overloade...

Page 8: ...damaged power supply line has been repaired Make sure the machine is stable Observe the maximum filling quantity of 225 kg per standard trolley corresponds to the max filling capacity of the drum 2 2...

Page 9: ...mains plug The power supply to the machine must be fuse pro tected with 16A secured with an AC DC sensitive ground fault circuit interrupter type B 3 Operating instructions Please refer to the short...

Page 10: ...ending on the user programs temperatures down to 10 C may be generated in the drum Take the correspond ing precautions Do not touch the tumbling arm mixing arm with your hands or any object when they...

Page 11: ...vac uum If this is the case the gasket has been mounted cor rectly Otherwise check the gasket The lid cannot be opened when there is a vacuum in the machine or if it has not yet been fully aerated If...

Page 12: ...n Appropriate material e g brushes rags is required and must be provided for the proper procedures of the above Cleaning products and disinfectants approved for the food prod uct area and suitable aga...

Page 13: ...leaning Somplex F fat solvent Somplex foam acidic Disinfectants Tego 2000 Tego IMC Supplier Th Goldschmidt AG Goldschmidtstr 100 D 45116 Essen Tel 49 201 1730 1 4 3 Cleaning procedure Please refer to...

Page 14: ...n permission from R hle customer ser vice if welding or cutting work is required on the ma chine Make sure when working on the electrical equipment of the machine that this is only done by qualified p...

Page 15: ...dard trolley support h Check the drum lid holder 5 2 Regular maintenance Regular maintenance of the machine must be carried out every 2000 hours of operation but at least once per year Maintenance sch...

Page 16: ...geration in staller and must then disposed of correctly 2 The following components contain oil a Lid drive b Tumbling arm drive c Slewing gear d Vacuum pump e Compressor cooling unit All gears motors...

Page 17: ...2 as per EN ISO 3744 Measuring instrument Br el Kj r Type 2240 The data on the type plate principally applies it is located at the rear of the machine next to the power supply line In case of deviati...

Page 18: ...essing machinery Basic concepts Part 2 Hygiene requirements Hygiene requirements DIN EN 60204 1 2007 06 A1 2009 10 Safety of machinery Electrical equipment of ma chines Part 1 General requirements Gen...