Tumbler MKR 600
16
5.3
Repair and spare parts
As a damaged part on a machine is usually damaged due to causes
unrelated to the part, always carry out a fault diagnosis.
For this reason, contact our Service Hotline at +49 7748 523-11 for
spare parts or technical faults. Please keep the machine type and
number ready.
6
Disposal
1.
The machine contains a cooling system filled with the refrig-
erant R404A. It must be pumped off by a refrigeration in-
staller and must then disposed of correctly!
2.
The following components contain oil:
a.
Lid drive
b.
Tumbling arm drive
c.
Slewing gear
d.
Vacuum pump
e.
Compressor (cooling unit)
All gears/motors except for the compressor are equipped with
oil draining screws. The compressor must be drilled open for
draining the oil. Subsequently, dispose of the oil properly!
3.
All other materials must be sorted and disposed of at a recy-
cling facility!
7
Technical documentation
7.1
Technical data
Connection voltage:
400 V
50/60 Hz 3-phase AC / N / PE
Power consumption:
6.8 kW
Full-load current:
14.6 A
Back-up fuse max.:
16 A
Protection class:
IP54