background image

Tumbler MKR 600

 

 

10 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

program will continue from that point at which it was in-
terrupted by the power failure. 

In its respective life cycle phases (transport, commission-
ing, setup, operation, cleaning, decommissioning, care / 
maintenance, dismantling / disposal) this machine is de-
signed for 1-person operation!  

When using this machine, no other person may be present 
near the machine. The exception (2-man operation): 

 

Installation and removal of drum lid 

 

Installation and removal of drum lid arms 

 

Installation and removal of tumbling arm 

 

Installation and removal of mixing arm 

 

Installation and removal of protective gearbox cover 

 

Transport of machine and machine parts 

Depending on the user programs, temperatures down to -
10 C may be generated in the drum. Take the correspond-
ing precautions. 

Do not touch the tumbling arm / mixing arm with your 
hands or any object when they are moving! Their rota-
tional speed while the lid is open is restricted for safety 
reasons! 

Make sure before each lifting operation that both stand-
ard trolleys sit correctly in the standard trolley support of 
the lifting aid! 

No persons or objects may be present in the swivel range 
of the drum! 

When emptying the drum corresponding appropriate pre-
cautions must be taken to ensure that no person stands in 
the discharge area of the machine! 

Make sure when mounting (or adjusting) the tumbling arm 
as well as the mixing arm (alternative blind plug) that 
they are correctly locked! 

No persons or interfering objects may be present in the 
swivel range of the lid! 

 
 

Summary of Contents for MKR 600

Page 1: ...ebensmitteltechnik Translation of the original instructions Tumbler Type MKR 600 R hle GmbH Beim Signauer Schachen 10 D 79865 Grafenhausen Tel 49 7748 523 11 Fax 49 7748 523 8511 www original ruehle d...

Page 2: ...Operating instructions 9 4 Cleaning instructions 12 4 1 Safety instructions 12 4 2 Cleaning agents and disinfectants 13 4 3 Cleaning procedure 13 5 Service Care maintenance repair 14 5 1 Regular care...

Page 3: ...e mains during this process Refrigeration installer These work activities may be carried out only by a re frigeration installer Disregard may result in injuries Warning of hot surface Warning of suspe...

Page 4: ...antling Wear eye protection Use light breathing mask The operator must operate the machine according to the intended use and strictly observe all points listed in the Operation work in structions prep...

Page 5: ...e been repaired the supervisor must ensure that the ma chine or parts of the machine are under no circumstances put into op eration The cleaning personnel must observe the work procedures from the Cle...

Page 6: ...cooling unit and cooling system may only be carried out by a refrigeration installer All life cycles phases Staying under the lifting aid standard trolley support is strictly prohibited and the stand...

Page 7: ...as is prohib ited Handling processing products and materials not belonging to food products is prohibited The lifting aid may be used only for the standard trolleys pro vided and must not be overloade...

Page 8: ...damaged power supply line has been repaired Make sure the machine is stable Observe the maximum filling quantity of 225 kg per standard trolley corresponds to the max filling capacity of the drum 2 2...

Page 9: ...mains plug The power supply to the machine must be fuse pro tected with 16A secured with an AC DC sensitive ground fault circuit interrupter type B 3 Operating instructions Please refer to the short...

Page 10: ...ending on the user programs temperatures down to 10 C may be generated in the drum Take the correspond ing precautions Do not touch the tumbling arm mixing arm with your hands or any object when they...

Page 11: ...vac uum If this is the case the gasket has been mounted cor rectly Otherwise check the gasket The lid cannot be opened when there is a vacuum in the machine or if it has not yet been fully aerated If...

Page 12: ...n Appropriate material e g brushes rags is required and must be provided for the proper procedures of the above Cleaning products and disinfectants approved for the food prod uct area and suitable aga...

Page 13: ...leaning Somplex F fat solvent Somplex foam acidic Disinfectants Tego 2000 Tego IMC Supplier Th Goldschmidt AG Goldschmidtstr 100 D 45116 Essen Tel 49 201 1730 1 4 3 Cleaning procedure Please refer to...

Page 14: ...n permission from R hle customer ser vice if welding or cutting work is required on the ma chine Make sure when working on the electrical equipment of the machine that this is only done by qualified p...

Page 15: ...dard trolley support h Check the drum lid holder 5 2 Regular maintenance Regular maintenance of the machine must be carried out every 2000 hours of operation but at least once per year Maintenance sch...

Page 16: ...geration in staller and must then disposed of correctly 2 The following components contain oil a Lid drive b Tumbling arm drive c Slewing gear d Vacuum pump e Compressor cooling unit All gears motors...

Page 17: ...2 as per EN ISO 3744 Measuring instrument Br el Kj r Type 2240 The data on the type plate principally applies it is located at the rear of the machine next to the power supply line In case of deviati...

Page 18: ...essing machinery Basic concepts Part 2 Hygiene requirements Hygiene requirements DIN EN 60204 1 2007 06 A1 2009 10 Safety of machinery Electrical equipment of ma chines Part 1 General requirements Gen...

Reviews: