Fig. 17
: Cross section of storage system
A
C
B
D
D
E
Function
5.1
Storage system
In heat storage/radiation systems, part of the heat pro-
duced by combustion is stored in the surround and then
used for heating the room through radiation.
Stored heat can also be released in the room by convec-
tion, through the aluminium duct and out through the hot-
air vents. Systems designed for heat storage only do not
have the duct and hot-air outlets.
A
:
Air vent
inlet (room air/circulating air)
(o
ptional)
B
:
AIR-Direct combustion air
inlet
(external air)
→ supplies external combustion air directly
to the fire compartment
C
:
Sealable fresh-air regulator
(external air)
D
:
Heat radiation
E
:
Air vent
outlet (hot air/feed air)
(optional)