PREMIUM-LINE
CUBEO
Manual
114
Fig. 9
:
Several fireplaces connected to the same
chimney
3.4
Thermal load
The parts of your fireplace are subject to high thermal loads. The used materials show very different ex-
pansion characteristics. Fast differences in temperature may result in damage to your fireplace.
3.5
Self-closing door
For safety reasons, systems connected to a single
chimney must be fitted with a self-closing door (model
A1).
It is forbidden, for example, to use the fireplace in
open-door mode for grilling food.
For adding wood to the fire or cleaning the ceramic
glass, the door must be kept open against a predefined
closing force.
3.6
Space in front of the fireplace
For solid-fuel fireplaces, a floor plate or fireproof flooring
must be placed in front of the door and extend outwards
by
at least 40 cm
.
The plate should extend widthways
at least 10 cm
from
either end of the fireplace door.
Note
Manipulations to the self-closing door are prohibited!
ATTENTION
Thermal load to system components during operation!
►
Never cool down the fireplace or parts of it using water or other liquids!
Fig. 10
: Space in front of the fireplace
X
X ≥ 40 cm
Y
≥ 10 cm
X
X
X
Y
Y
Summary of Contents for Premium-Line Cubeo
Page 2: ......
Page 28: ......
Page 54: ......
Page 80: ......
Page 106: ......
Page 132: ...PREMIUM LINE CUBEO Manual 132...
Page 133: ...PREMIUM LINE CUBEO Manual 133 Notizen Notes Note Opmerkingen Notes...
Page 134: ...PREMIUM LINE CUBEO Manual 134...
Page 135: ......
Page 136: ...www ruegg cheminee com 89 90 00405 ba_cubeo_rev1_de fr it nl en_06 2012...