Safety 

 

 

2.1 General  

 

This operating manual provides important information concerning operation and maintenance 
of the installation that must be observed. Authorised personnel/the operator must read the 
manual carefully before going into operation and the manual must be kept in direct proximity 
of the installation.  
 

2.2 Qualification and training personnel 

 

 

Any work on the compressor such as operation and maintenance shall only be carried out by 
authorised, skilled and qualified personnel, who are familiar with the applicable safety 
regulations. Repairs, maintenance and conversion work shall only be carried out by 
authorised personnel.  
 

2.3 Operating safety conscious 

 

 

Essential safety regulations relating to the setting up, operation and maintenance of air 
compressors are covered by the following publications:  
- Regulations for the prevention of accidents, in particular:  
• VBG 16 compressors  
- Standards, in particular:  
• DIN EN 12100 Safety of machines  
• DIN EN 1012-1 Compressors and vacuum pumps, safety requirements  
 
The latest edition of each of these regulations shall be applicable. Any special official codes 
and regulations, particularly safety regulations applicable to your operation in view of the 
local conditions shall be observed likewise. In the event of competing regulations, the most 
severe requirements shall apply. 

 

 

2.4 Safety instructions operator 

 

 
Securing the compressor’s operational safety is the responsibility of the operator. Damaged 
or non-functioning parts must be replaced immediately. If combustible materials are to be 
handled by the compressor, it shall be ensured that the spontaneous-ignition temperature of 
any dust/air mixture will not be reached. VBG 16 prescribes that a temperature limit of max. 
120°C should not be exceeded (measuring point prior to contact with the conveyed product).  

 
2.5 Modifications and repairing spare parts 

 

 

Unauthorized repair work and modifications are not permitted. Warranty doesn’t apply to 
installations with a damaged seal. Original spare parts and accessories approved by the 
manufacturer contribute to safety. Using foreign spare parts and accessories may entail the 
loss of any liability for the consequences arising therefrom.  

 
2.6 Modifications installation 

 

 

Without approval from RTI, it is not permitted to make any alterations to the installation.

 

 

 

Summary of Contents for SiloKing 1100 LS

Page 1: ...INSTRUCTION AND OPERATING MANUAL RTI Compressor unit with electric motor SiloKing 1100 LS These pictures are only examples...

Page 2: ...interference free operation and to achieve longevity Repairs maintenance or conversion work shall only be carried out by authorised trained and qualified personnel that are familiar with the current...

Page 3: ...3 Operating safety conscious 2 4 Safety instructions operator 2 5 Modifications and repairing spare parts 2 6 Modifications unit 3 Commissioning 3 1 Set up 3 2 Operating elements and monitoring gauges...

Page 4: ...ontact details Please mention the PO number when contacting us by phone or mail You will find the PO number on the type plate of the installation Telephone number 0031 544 377050 Fax 0031 544 376499 E...

Page 5: ...oil free Power 52 kW at 2 bar and 2930 rpm Driven by 55 75 kW electrical motor Technical data electrical motor Power 55 kW 400 Volt 75 kW 400 Volt Manufacturer Elsto Elsto Type 250 L 2 A 280 L 4 B Bu...

Page 6: ...sure that the distribution pipes and pipe connections are of the correct size and suitable for the respective operating pressure Install the unit in a place where the ambient air is as cool and clean...

Page 7: ...ection Important Any work on the compressor such as operation and maintenance shall only be carried out by authorised skilled and qualified personnel who are familiar with the applicable safety regula...

Page 8: ...ulations shall be applicable Any special official codes and regulations particularly safety regulations applicable to your operation in view of the local conditions shall be observed likewise In the e...

Page 9: ...air filter 3 3 Start up motor compressor Provide for electrical power connection Check phase circuit direction of rotation control light green ok red set main switch to 2 Press start button green Chec...

Page 10: ...r if necessary see operating instructions for compressor chapter Maintenance Air filter indicator Negative pressure is indicated on the air filter indicator of the compressor unit Important If the 65...

Page 11: ...To prevent overheating in the enclosure the valve at the silo tank must blow off before the compressor valve does blow off pressure 2 5 bar D Pay attention to any unusual sounds or peculiarities near...

Page 12: ...D Check the functioning of the safety valve Air pressure measured at the discharge flange of the compressor may not exceed a maximum gauge pressure of 2 5 Potential pressure loss between compressor an...

Page 13: ...he sound cover only when the compressor is at standstill Caution Burning hazard due to hot machine parts Wear protective gloves 4 2 V belt drive Check the tension of the V belts and asses the wear of...

Page 14: ...Drive speed to high Adjust drive speed Defective non return valve Replace non return valve Safety valve does not blow off Check safety valve Negative pressure gauge reading 65 mbar Suction filter clog...