Commissioning  

 
3.1  

Set-up 

 

Mount the compressor unit in horizontal position, if possible. If the unit is not mounted 
horizontally, please observe the specified limit values. 

 
Important!! 

Maximum permissible angles of tilt during operation:  
forward and backward: 10°  
to the right and left: 10° 

 
3.2  

Operating elements and monitoring gauges 

 

  Start button  

  Stop button  

  Phase switch  

  Operation control lamp (direction of rotation)  

  Compressor oil pressure gauge  

  Maintenance indicator of compressor air filter 

 

3.3  

Start-up motor/compressor 

 

  Provide for electrical pow er connection 

  Check phase circuit/direction of rotation (control 

light “ green”  ok – “ red”  set 

main sw itch to 2)  

  Press 

start button “ green”  

  Check start procedure  

 
Important!! 

Start the compressor unit completely relieved of load only.  
Never start the unit trying to overcome any backpressure that may exist.     

 
 
3.4  

Shut down motor/compressor 

 

  Relieve compressor discharge pipe 

 

Press stop button “ red”  

  Wait for shutdow n  

 

“ Emergency off”  in case of failure 

 

3.5  

Monitoring motor operation 

 

  Main sw itch position 0-1-2 

 

Phase control “ green”  ok, if “ red”  
sw itch to position 2 

 

Temperature control “ red”  – unit 
sw itches off  

  Compressor 

operation “ green”  ok 

 
 

 

Summary of Contents for SiloKing 1100 LS

Page 1: ...INSTRUCTION AND OPERATING MANUAL RTI Compressor unit with electric motor SiloKing 1100 LS These pictures are only examples...

Page 2: ...interference free operation and to achieve longevity Repairs maintenance or conversion work shall only be carried out by authorised trained and qualified personnel that are familiar with the current...

Page 3: ...3 Operating safety conscious 2 4 Safety instructions operator 2 5 Modifications and repairing spare parts 2 6 Modifications unit 3 Commissioning 3 1 Set up 3 2 Operating elements and monitoring gauges...

Page 4: ...ontact details Please mention the PO number when contacting us by phone or mail You will find the PO number on the type plate of the installation Telephone number 0031 544 377050 Fax 0031 544 376499 E...

Page 5: ...oil free Power 52 kW at 2 bar and 2930 rpm Driven by 55 75 kW electrical motor Technical data electrical motor Power 55 kW 400 Volt 75 kW 400 Volt Manufacturer Elsto Elsto Type 250 L 2 A 280 L 4 B Bu...

Page 6: ...sure that the distribution pipes and pipe connections are of the correct size and suitable for the respective operating pressure Install the unit in a place where the ambient air is as cool and clean...

Page 7: ...ection Important Any work on the compressor such as operation and maintenance shall only be carried out by authorised skilled and qualified personnel who are familiar with the applicable safety regula...

Page 8: ...ulations shall be applicable Any special official codes and regulations particularly safety regulations applicable to your operation in view of the local conditions shall be observed likewise In the e...

Page 9: ...air filter 3 3 Start up motor compressor Provide for electrical power connection Check phase circuit direction of rotation control light green ok red set main switch to 2 Press start button green Chec...

Page 10: ...r if necessary see operating instructions for compressor chapter Maintenance Air filter indicator Negative pressure is indicated on the air filter indicator of the compressor unit Important If the 65...

Page 11: ...To prevent overheating in the enclosure the valve at the silo tank must blow off before the compressor valve does blow off pressure 2 5 bar D Pay attention to any unusual sounds or peculiarities near...

Page 12: ...D Check the functioning of the safety valve Air pressure measured at the discharge flange of the compressor may not exceed a maximum gauge pressure of 2 5 Potential pressure loss between compressor an...

Page 13: ...he sound cover only when the compressor is at standstill Caution Burning hazard due to hot machine parts Wear protective gloves 4 2 V belt drive Check the tension of the V belts and asses the wear of...

Page 14: ...Drive speed to high Adjust drive speed Defective non return valve Replace non return valve Safety valve does not blow off Check safety valve Negative pressure gauge reading 65 mbar Suction filter clog...