RESPIRATOR SETUP AND CARE

Insert the helmet into the hood with front of 
the Helmet towards the lens of the hood.

Do the same thing on the other side to fully 
secure the lens and the hood to the Helmet.

Line up the tabs of the lens with the clips 
on the sides of the helmet. 1. Slide the 1st 
side under the front side of the clip and slide 
back. 2. Snap the 2nd side of over the back 
of the clip.

PLACING THE HELMET INTO THE HOOD

FIGURE 2.1

1.

2.

FIGURE 2.2

1.

2.

FIGURE 2.3

The T-LINK

®

 Supplied Air Respirator must be supplied with 

respirable air meeting the requirements of EN 12021 (AS/NZS 1715) or higher quality and 
meets other governing body requirements. The moisture content of the breathable air 
should controlled within the limits in accordance with EN 12021, to avoid the air freezing 
the apparatus. Do not use oxygen enriched air.

WARNING

Summary of Contents for T-Link

Page 1: ...MANUAL AND OTHER LANGUAGES rpbsafety com respirators t link The Respiratory Protection Brand ENGLISH 2 NEDERLANDS 37 EN NL INSTRUCTION MANUAL EN14594 2005 3B EN12941 1998 A2 2008 TH3 P R SL RESPIRATO...

Page 2: ...TS AND ACCESSORIES 30 WARRANTY AND LIABILITY STATEMENT 36 NEDERLANDS 37 CONTENTS RPB Safety LLC is an ISO9001 certified company EXPLANATION OF SIGNAL WORDS AND SYMBOLS The following signal word and sa...

Page 3: ...ions designs industrial designs copyrights software source code database rights moral rights inventions techniques technical data trade secrets know how brands trademarks trade names slogans logos and...

Page 4: ...pends on the setup of the airline filter see the RPB RADEX Instruction Manual HAZARD LIMITATIONS The RPB T LINK Respirator is NOT FOR USE if In atmospheres immediately dangerous to life or health IDLH...

Page 5: ...and is not a substitute for good safety practices and engineering controls HEAD The T LINK when equipped with the standard lightweight helmet is designed to act as a bump cap with minimal head protec...

Page 6: ...arts that may cause an ignition in flammable or explosive atmospheres J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s User s Instruction...

Page 7: ...s instructions J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selected fitted used and maintained in accordance with applicable...

Page 8: ...ate the air source in a clean air environment always use a filter on the inlet of your air source Make sure the air source is somewhere that vehicles forklifts and other machinery are not running near...

Page 9: ...rson should determine what kind of respiratory face and eye head and hearing protection is appropriate for the intended activities and environments of use For example select a respirator appropriate t...

Page 10: ...the content of this Instruction Manual and the approved air supply device Instruction Manual and standard or regulatory requirements Ensure that each intended user reads both these manuals Ensure that...

Page 11: ...athing Air Line SAR PX5 or the PX4 AIR PAPR See Respirator Component Diagram page 6 7 The RPB T LINK is only approved to be used with the RPB PX5 PX4 AIR PAPR RPB C40 Climate Control Device or the RPB...

Page 12: ...er Instruction Manual Make sure the area is ventilated and monitored Make sure that the area is well ventilated and that regular air samples are taken to confirm the atmosphere stays within the levels...

Page 13: ...surfaces Do not apply paints solvents adhesives or self adhesive labels except as instructed by RPB This product may be adversely affected by certain chemicals See the Respirator Setup and Care sectio...

Page 14: ...nimum required air pressure at the point of attachment for the length of air supply hose will decrease the level of protection provided Check that the capacity of the air supply systems can provide su...

Page 15: ...f the clip and slide back 2 Snap the 2nd side of over the back of the clip PLACING THE HELMET INTO THE HOOD FIGURE 2 1 1 2 FIGURE 2 2 1 2 FIGURE 2 3 The T LINK Supplied Air Respirator must be supplied...

Page 16: ...cation the respirator will be used in FIGURE 3 3 POWERED AIR RESPIRATOR SETUP AND CARE CONTINUED Without a hood on the T LINK helmet assembly insert the breathing tube adapter into the inlet of the T...

Page 17: ...ir Supply Hose to the point of attachment 04 900 Radex Airline Filter shown SUPPLIED AIR Connect the Breathing Tube to the flow control device NOTE Check the hose connections for any air leaks and tig...

Page 18: ...EAD HARNESS ADJUSTMENT The position of the head harness can be adjusted by loosening the screws that hold the front bracket and sliding it forward or backwards into the desired slot Once in position t...

Page 19: ...pivot points Slide the tab on the side pad covers into one of the three T shaped slots in the head harness depending on the desired height of the side pads Reinsert the ratchet pivot points Slide the...

Page 20: ...e side pad covers SIDE PADDING SYSTEM CLEANING AND DISINFECTING CLEAR VISION CASSETTE LENSES Peel off the backing of the cassette lenses and apply the lenses to the outside of the lens sewn into the h...

Page 21: ...with mild detergent or replace it with a new one Replace the brow pad by wrapping the brow pad over the head harness with the flat side facing inwards Stretch the pad around the head harness and secu...

Page 22: ...Impact Liner with hook and loop Pull the comfort pad out of the helmet To remove the Impact Liner remove the head harness bracket by removing the screws holding it in place The comfort pad can be was...

Page 23: ...r bib down over your shoulders and make sure it is laying flat on your chest and back so that it does not get in the way of your work DONNING AND DOFFING Open the bottom of the hood with the air flowi...

Page 24: ...to store in a container or a bag Store in a cool dry place between 10 C to 45 C 14 F to 113 F 90 RH PX5 or the PX4 AIR may need to be stored separately refer to the PX5 or the PX4 AIR Instruction manu...

Page 25: ...NOTES...

Page 26: ...the type used Attach the PTT to your belt so your elbow can activate the Button Connect the PTT cable to the head set cable and place the cable underneath the cape To operate the device press your elb...

Page 27: ...nication can be installed on either side of the helmet Attach the side pad back onto the cover over the Communication Insert the side pad back into the helmet Place the Communication ear piece into th...

Page 28: ...X780 09 930 MOTOROLA AXU4100 AXV5100 BPR40 CLS1110 CLS1410 CLS1413 CLS1450C CLS1453C CP100 CP150 CP185 CP200 CP88 CT125 CT150 CT250 CT450 CT450LS DTR DTR410 DTR550 DTR650 GP200 GP2000 GP300 GP308 GP68...

Page 29: ...518X Ascend ES Series MOTOROLA GP900 GP9000 HT1000 MT1500 MT2000 MTS2000 MTX8000 MTX838 MTX900 MTX9000 MTX960 MTXLS PRI500 X1500 XTS1500 XTS2000 XTS2500 XTS3000 XTS3500 XTS5000 GP1200 09 934 HYT TC 2...

Page 30: ...30 PARTS AND ACCESSORIES 2 8 9 10 11 13 4 1 5 15 16 14 12 7 5 3 FIGURE 16 1 19 20 18 17 21 6...

Page 31: ...and Air Director 16 525 11 LINK System Head Harness 16 531 12 LINK System Ratchet Adjuster Assembly 16 530 13 LINK System Head Harness Brow Pad 16 526 14 LINK System Side Padding System 16 520 S 15 L...

Page 32: ...rt Number 1 PX5 PAPR and Belt 03 801 2 Breathing Tube for PX5 PAPR 04 831 3 Flow Meter PX5 PAPR 03 819 4 PX4 AIR PAPR and Belt 03 901 5 Breathing Tube for PX4 AIR PAPR 04 837 6 Flow Meter PX4 AIR 04 0...

Page 33: ...Part Number 1 Breathing Tube for Supplied AIr 04 833 2 Constant Flow Valve Assembly and Belt 03 102 3 C40 Climate Control Assembly and Belt 03 502 4 Belt for Constant Flow Valve NV2022 5 2 Belt for C...

Page 34: ...ES AND FITTINGS TABLE 2 1 25ft 50ft 100ft SERIES 1 COUPLERS 2 PLUGS 3 BREATHING AIR LINE ASSEMBLIES RPB Quick Disconnect 03 022 CF CEJN Coupler 04 322 25 RPB 7 5m 9 5mm 04 322 50 RPB 15m 9 5mm 04 322...

Page 35: ...er 1 Comms Link Communication System w 09 913 16 922 2 PTT 09 913 3 Comms Link Clip 16 529 4 Two Pin 09 930 5 Multi Pin 09 931 6 Multi Pin 09 932 7 Two Pin 09 933 8 Multi Pin 09 934 9 One Pin 09 935 O...

Page 36: ...occurs RPB will repair or replace the defective Product or a component of the Product in its sole discretion This repair or replacement remedy is the sole and exclusive remedy under this limited warra...

Page 37: ...ht oog gezichtsbescherming en hoofdbescherming nodig is zoals schilderen chemische behandeling en andere industri le toepassingen Wanneer het Zytec materiaal wordt gebruikt kan de kap worden gebruikt...

Page 38: ...e 1 866 494 4599 of e mail customerservice rpbsafety com Formulier 7 20 544 Herziening 6 BELANGRIJKE VEILIGHEIDSINFORMATIE Onjuiste selectie pasvorm gebruik of onderhoud van dit product kan tot letsel...

Page 39: ...als De atmosfeer onmiddelijk gevaar levert voor leven of gezondheid De drager niet kan ontsnappen zonder hulp van het ademhalingstoestel Het percentage zuurstof in de omgeving lager ligt dan 21 1 Bij...

Page 40: ...3 hoofdcomponenten zoals te zien in Afbeelding 1 1 Alle 3 de componenten moeten aanwezig zijn en correct gemonteerd zijn om een compleet gekeurd motoraangedreven luchtzuiverend ademhalingstoestel te v...

Page 41: ...nwijzing J Als dit product niet op de juiste manier wordt gebruikt en onderhouden kan dit letsel of de dood tot gevolg hebben M Alle goedgekeurde ademhalingstoestellen moeten worden geselecteerd gepas...

Page 42: ...e ademluchtsystemen b v cilinders Het verbinden van de ademluchtslang met een niet adembare luchtbron zal tot ernstig letsel of de dood leiden ADEMLUCHTSLANGEN EN FITTINGEN RPB ademluchtslangen en fit...

Page 43: ...erlener medische evaluaties uitvoeren met behulp van een medische vragenlijst of een standaard medisch onderzoek Train medewerkers in het gebruik onderhoud en de beperkingen van de T LINK Benoem een g...

Page 44: ...er of u alle benodigde onderdelen heeft zodat de T LINK functioneert als een volledig en gekeurd ademhalingstoestel Luchtkap T LINK Ademhalingsslang en Regelaar SAR Constantvolumeregelaar of C40 Klima...

Page 45: ...Nadat het verontreinigingsniveau is bevestigd bepaalt u het juiste filterpatroon voor de toepassing om te zorgen dat u voldoende beschermd bent Volg de Gebruiksaanwijzing van de PX5 of de PX4 AIR PAP...

Page 46: ...er liggen dan de aanbevolen concentraties voor dit toestel Volg alle procedures voor het betreden bedienen en verlaten van besloten ruimten zoals gedefinieerd in geldende voorschriften en normen ADEML...

Page 47: ...de achterkant van de clip AFBEELDING 2 3 OP PAGINA 15 Doe hetzelfde aan de andere kant om het vizier en de kap volledig op de helm te bevestigen DE ADEMHALINGSSLANG VERBINDEN AFBEELDING 3 1 OP PAGINA...

Page 48: ...de Ademluchtdruktabel pagina 14 AANPASSEN HOOFDBANDENSTEL AFBEELDING 5 1 OP PAGINA 18 De hoofdband kan strakker of losser worden gemaakt met behulp van de ratelknop op de achterkant van de hoofdband A...

Page 49: ...G 10 4 OP PAGINA 22 Draai de Schokdemper uit de huls van de helm De binnenkant van de huls kan worden afgeveegd met een mild vloeibaar reinigingsmiddel of een reinigingsdoekje AAN EN UITTREKKEN DE KAP...

Page 50: ...mogelijk afzonderlijk worden opgeslagen raadpleeg de PX5 en de PX4 AIR Gebruiksaanwijzing voor specifieke instructies betreft opslag Na gebruik AFBEELDING 12 1 OP PAGINA 24 Lange termijn opslag of tr...

Page 51: ...S T LINK Zytec Veiligheidsvizier 17 711 2 T LINK Lichtgewicht Huls voor Helm 17 511 3 LINK Huls voor Veiligheidshelm 16 511 4 LINK Kaakstuk 16 514 5 T LINK Vizierklemmen Links en Rechts Paar 17 512 6...

Page 52: ...rtragend 07 765 FR REGELAAR AFBEELDING 16 3 OP PAGINA 33 Item Nummer Beschrijving Onderdeel Nummer 1 Ademhalingsslang voor Ademlucht 04 833 2 Constantvolumeregelaar en riem 03 102 3 C40 Klimaatregelin...

Page 53: ...al RPB naar eigen goeddunken het defecte Product of een onderdeel van het product repareren of vervangen Deze reparatie of vervanging oplossing is de enige en exclusieve remedie onder deze beperkte ga...

Page 54: ...54 NOTES...

Page 55: ...55 NOTES...

Page 56: ...ficient operating for up to 8 hours on a single charge RPB QUIET LINK EAR DEFENDERS The RPB QuieT LINK ear defender system fits directly to the Z LINK and T LINK with no modifications Combine with RPB...

Reviews: