11
PRODUCT USER SAFETY INSTRUCTIONS
BEFORE INITIAL USE - BE TRAINED AND MEDICALLY QUALIFIED
Do not use this respirator until you have read this manual and the PX5
®
, PX4 AIR
®
PAPR or the
flow control device Instruction Manual (additional copies available at rpbsafety.com) and been
trained in the respirator’s use, maintenance, and limitations by a qualified individual (appointed by
your employer) who is knowledgable about the RPB
®
T-LINK
®
Respirator.
Do not wear this respirator until you have passed a medical evaluation using a medical
questionnaire or an initial medical examination by a qualified physician or other licensed health
care professional (PLHCP).
Allergens:
No known common allergens are used in this product.
Some materials could cause an allergic reaction in susceptible individuals. If you have a known
allergy or develop irritation, inform your employer. Irritation may occur from lack of cleaning.
Follow all cleaning and care instructions provided in the instruction manuals for this and any
other RPB
®
products you are using.
MAKE SURE THE SYSTEM IS READY FOR USE
Make sure you have a complete system.
Verify that you have all required components for the
T-LINK
®
to serve as a complete approved respirator:
Respirator Hood Assembly (T-LINK
®
)
Breathing Tube Assembly and Flow Control Device (SAR - Constant Flow Valve or
C40
®
Climate Control Device)
Breathing Air Line (SAR), PX5
®
or the PX4 AIR
®
(PAPR)
See Respirator Component Diagram (page 6-7).
The RPB
®
T-LINK
®
is only approved to be used
with the RPB
®
PX5
®
, PX4 AIR
®
PAPR, RPB
®
C40
™
Climate Control Device, or the RPB
®
Constant
Flow Valve. Use only authentic RPB
®
brand parts and components that are part of the approved
respirator assembly. Using incomplete or inappropriate equipment, including the use of counterfeit
or non-RPB
®
parts, can result in inadequate protection and will void the approval of the entire
respirator. Do not modify or alter any part of this product.
Inspect
all components daily for signs of damage or wear and tear that may reduce the level of
protection originally provided. Remove any damaged component or product, including any hood
or helmet that has been subject to impact, from service until repaired or replaced. Scratched or
damaged lenses or other components should be replaced with genuine RPB
®
brand replacement
parts. When the hood is replaced, make sure to remove any additional protective film from both
sides of the lens. If the film is left in place, it could affect the optical clarity of the lens and cause
eye strain. Inspect the inside of the respirator for respirable dust or other foreign objects. Keep the
inside of the respirator clean at all times.
Make sure that the helmet is correctly assembled
in the configuration that suits your application.
An incomplete or improperly installed hood could provide inadequate impact and respiratory
protection.
See Respirator Setup and Care (page 16) See Donning (page 25) for fit information.
Summary of Contents for T-Link
Page 25: ...NOTES...
Page 30: ...30 PARTS AND ACCESSORIES 2 8 9 10 11 13 4 1 5 15 16 14 12 7 5 3 FIGURE 16 1 19 20 18 17 21 6...
Page 54: ...54 NOTES...
Page 55: ...55 NOTES...