Always check the interior of the respirator for contaminants before
donning. Always don and doff the helmet while outside the work area, keeping the interior
of the helmet clean and free of contaminants. Not doing these steps could expose you to
hazardous materials, and contaminants that could impair the function of the respirator.
WARNING
Before storing the respirator, clean the unit following the cleaning instructions in this
instruction manual. Be sure it is clean, both inside and out. After use, store the respirator by
hanging it up in a clean, dry place, away from the work area. If the T-LINK
®
isn’t going to be
used for a longer period of time or for transportation, it is recommended to store in a container
or a bag. Store in a cool dry place between -10°C to +45°C (14°F to 113°F) <90%RH. PX5
®
or
the PX4 AIR
®
may need to be stored separately, refer to the PX5
®
or the PX4 AIR
®
Instruction
manual for specific storage instructions.
After use:
Long term storage or transportation:
STORAGE
FIGURE 12.1
FIGURE 12.2
DOFFING YOUR HELMET
When you have finished working, keep the respirator on with air flowing into the helmet until
you have left the contaminated area. Depending on the contaminants, it may be advisable
to clean the exterior of the helmet and your work garments before removing the respirator. A
workplace cleaning program may be necessary.
INSPECTION
If the hood is contaminated or show excessive wear, dispose of the hood according to federal
and local regulations. Keep the helmet, breathing tube, and other parts for future use if they
are in good condition.
DONNING AND DOFFING