Cup Test
Pressing <enter> at
Cup Test
will cause the vender to actuate the plunger in the cup. This test allows service
personnel to observe if there are any problems with the cup plunger that would inhibit vending.
Testing
will be
displayed while this test is carried out.
Test Complete
will be displayed when the vender has completed this test.
Pressing <exit> will terminate the test.
Note:
The delivery test will only start if the door is OPEN.
Possible problems:
A. Plunger does not extend out from cup
B. Plunger does not spin
A. Plunger does not extend out from cup. (Refer to Figure 5.4.)
1. Remove the top of the cup, and check the harness connection at pinout P3 on the cup logic board.
(Refer to
Figure 5.5.)
Make sure there are no loose wires and the connection is tight.
2. Using an ohmmeter, check for continuity on all wires in the harnessing from the DMC to the cup logic board.
If
any
wire fails, replace the harness. If
all
wires pass, replace the cup logic board. If the problem persists,
replace the plunger motor.
(Refer to Figure 5.6.)
Plunger
FIGURE 5.4.
Location of cup plunger
Use Cup Test to actuate the plunger.
FIGURE 5.5.
Location of position P3
Make sure the harness at the connection on the
logic board is tight, with no wires loose, backed
out, etc.
Position P3
FIGURE 5.6.
View of inside of cup from above
Cup logic board
Plunger motor
Driver motor