29
RVV Gen II KO Service and Parts Manual
SECTION 3: Vender Programming
Correct Change
If <enter> is pressed at the “Correct Change” prompt, the
display will show “Consumer Overpay X.” Using <up>
or <down> will cycle through all available correct change
options, as listed below. Pressing <exit> at any point in
this procedure will return to the “Correct Change” prompt
without saving any changes. Use <up> to proceed to the
next prompt, “Preview Password.”
•
Consumer Overpay X
This submode is used to determine whether a vend
should be allowed when an overpayment situation may
result. If set to “0,” the customer will not be cheated.
When set to “1,” if a customer makes a selection
when the change levels are low and the “Use Correct
Change Only” message is:
• OFF: The message will continue to scroll for up
to one minute. If after 2 seconds but before one
minute expires the customer re-selects this same
selection, the vend will continue and as much
change as possible will be returned.
• ON: The message will continue to scroll for up to
one minute. However, the vend will continue and
as much change as possible will be returned.
In either case above, remaining change due back
to the customer will remain on the display. The
customer could add change to the remaining value on
the display to make another vend.
Note: If “Consumer Overpay” is set to 1, both “Corr
Chg Value” and “Uncond Accept” will apply; if set to
0, only “Corr Chg Value” will apply.
•
Corr Chg Value (Correct Change Value)
When <enter> is pressed at “Corr Chg Value,” the
display will show a value. The changer must be able
to pay back this value and all values below that (in
increments of the changer’s lowest tube value) in
order for the correct-change message to remain off.
In other words, if “Corr Chg Value” is set to 0.25,
the changer must be able to pay back 0.25, 0.20, 0.15,
0.10, and 0.05 in any combination, or else the correct-
change message will scroll. If this value is set to 0.00,
the “Use Correct Change Only” message will never
scroll.
•
Uncond Accept (Unconditional Acceptance Value)
When <enter> is pressed at “Uncond Accept,” the
display will show a value. The vender should not
accept any amount of currency (bill or coin) larger
than the value set in “Uncond Accept” unless the
changer can pay out the equivalent of that amount.
Preview Password
If <enter> is pressed at the “Preview Password” prompt,
the controller will display the current password for
the external menu. The first digit of the number will
be flashing. Pressing <up> or <down> will adjust the
currently flashing digit up or down. Pressing <enter>
will save the currently flashing digit and cause the next
digit of the password to begin flashing. All digits may be
modified in this manner. Pressing <exit> at any point in
the procedure will save the currently displayed password
and return you to the “Preview Password” prompt. From
the “Preview Password” prompt, use <up> to proceed to
the next prompt, “Language Select.”
Language Select
If <enter> is pressed at the “Language Select” prompt,
the controller will display the current language setting.
Pressing <up> or <down> will sequence through the
available language settings: English, French, German,
Italian, Portuguese, Spanish, Slovene, Finnish, Norwegian,
and Custom. Pressing <enter> at any point in the
procedure will save the currently displayed language
setting and return you to the “Language Select” prompt.
Custom language is present only if custom language has
been uploaded using DEX. From the “Language Select”
prompt, use <up> to proceed to the next prompt, “Time
Programming.”