Roundup ES-1200 Owner'S Manual Download Page 4

EGG STATION (ES-1200)

4

A.J. Antunes & Co.

P/N 1011119 Rev. B 03/12 

ImPOrTANT sAfETy INfOrmATION

in addition to the warnings and cautions in this manual, 

use the following guidelines to safely operate the unit:

  •  Read all instructions before using equipment.
  •  For your safety, the equipment is furnished with 

a properly grounded cord connector.  Do NOt 

attempt to defeat the grounded connector.

  •  Install or locate the equipment only for its intend

-

ed use as described in this manual.  Do NOt use 

corrosive chemicals in this equipment.

  •  Do NOT operate this equipment if it has a dam

-

aged cord or plug, if it is not working properly, or 

if it has been damaged or dropped.

  •  This equipment should be serviced by qualified 

personnel only.  contact the nearest Roundup 

authorized service agency for adjustment or 

repair.

  •  Do NOT block or cover any openings on the unit.
  •  Do NOT immerse cord or plug in water.
  •  Keep cord away from heated surfaces.
  •  Do NOT allow cord to hang over edge of table or 

counter.

  • 

a hood may be required. Please consult with your 

local health and safety officials prior to installa-

tion.

The following warnings and cautions appear 

throughout this manual and should be carefully 

observed.
  •  Turn the power off, unplug the power cord, 

and allow unit to cool down before performing 

any service or maintenance.

  •  The equipment should be grounded accord

-

ing to local electrical codes to prevent the 

possibility of electrical shock.  It requires a 

grounded receptacle with separate electrical 

lines, protected by fuses or circuit breaker of 

the proper rating.

  •  All electrical connections must be in accor

-

dance with local electrical codes and any 

other applicable codes.

  •  WARNINg ElECTRICAl ShOCk hAzARD.  

fAIlurE TO fOllOw ThEsE INsTrucTIONs 

COulD RESulT IN SERIOuS INJuRy OR 

DEATh.

- Electrical ground is required on this unit.

-  Do NOT modify the power supply cord 

plug.  If it does not fit the outlet, have a 

proper outlet installed by a qualified elec-

trician.

-  Do NOT use an extension cord with this 

appliance.

-  Check with a qualified electrician if you 

 

are unsure if the appliance is properly 

grounded.

  •  If the supply cord is damaged, it must be 

replaced by the manufacturer or its service 

agent.

  •  Do NOT clean this appliance with a water jet.
  •  Do NOT use a sanitizing solution or abrasive 

materials. The use of these may cause dam-

age to the stainless steel finish.

  • 

chlorides or phosphates in cleaning agents 

(e.g. bleach, sanitizers, degreasers, or deter

-

gents) could cause permanent damage to 

stainless steel equipment.  The damage is 

usually in the form of discoloration, dulling 

of metal surface finish, pits, voids, holes, or 

cracks.  This damage is permanent and NOT 

covered by warranty.

  •  The following tips are recommended for main

-

tenance of your stainless steel equipment:

-  Always use soft, damp cloth for cleaning, 

rinse with clear water, and wipe dry.  when 

required, always rub in direction of metal 

polish lines.

-  routine cleaning should be done daily 

using soap, ammonia detergent, and water.

-  Stains and spots should be removed using 

a vinegar solution.

-  Finger marks and smears should be 

removed using soap and water.

-  hard water spots should be removed using 

a vinegar solution.

Summary of Contents for ES-1200

Page 1: ...P N 1011119 Rev B 03 12 Egg Station Model ES 1200 Owner s Manual Manufacturing Numbers 9300590 A S D L I S T E CM O I N NIT A T...

Page 2: ...e back cover of this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the...

Page 3: ...e agency directory and fill in the information below Authorized Service Agency Name Phone No Address Use only genuine Roundup replacement parts in this unit Use of replacement parts other than those s...

Page 4: ...ical lines protected by fuses or circuit breaker of the proper rating All electrical connections must be in accor dance with local electrical codes and any other applicable codes Warning electrical sh...

Page 5: ...al Cord Plug Configurations Model Mfg No Plug Description Plug Configuration ES 1200 9300590 Power Cord Twist Lock L6 20P Electrical Ratings Model Mfg No Volts Watts Amp Hertz ES 1200 9300590 208 220...

Page 6: ...e use 5 Clean the Service Pans and Side Panel in hot soapy water Rinse in clear water and allow to air dry 6 Reassemble all parts to unit Caution All electrical service connections must be in accordan...

Page 7: ...erature 6 Use the scraper to clean the Grill Surface and move waste into the Grease Catch Pans Operating Procedure Read these instructions prior to cooking eggs 1 Ensure that the unit is set on a leve...

Page 8: ...nd START STOP buttons simultaneously for five seconds The indicator lights will blink 2 Continue to hold the TIME 1 button until the Ready Bacon and Cooking Lights are blinking This sequence means the...

Page 9: ...ent and not covered by warranty The following tips are recommended for maintenance of your stainless steel equipment Always use soft damp cloth for cleaning rinse with clear water and wipe dry When re...

Page 10: ...mperature at the middle of the Platen surface Figure 2 The temperature should be approximately 15 F of 350 F 177 C If temperature is within range proceed to Step 3 If temperature is above or below ran...

Page 11: ...uthorized Service Agency Inoperable Platen Low voltage Inoperable Hi Limit Thermostat Inoperable Thermocouple Inoperable Solid State Relay Incorrect amount of water added to trough in cover Fill troug...

Page 12: ...and back on The Green LED blinks on and off 3 times pauses for 2 seconds and repeats Open or disconnected Thermocouple In this state the unit turns off the control signal to the Solid State Relay and...

Page 13: ...AC 230VAC BOARD SWITCH THERMO COUPLE T4 T3 18 GA TFE 200 C UNLESS OTHERWISE SPECIFIED 22 GA TFE 200 C NOTE ALL WIRES TO BE 14 GA TFE 200 C HEATER GRN GRN YEL BLK BRN WHT BLU POWER CORD T2 T1 P2 P1 P3...

Page 14: ...EGG STATION ES 1200 14 A J Antunes Co P N 1011119 Rev B 03 12 Replacement Parts 10 12 7 3 10 9 14 17 30 32 38 39 40 13 11 5 34 4 37 2 33 42 31 41 36 35 44 6 15 16 8 1 43...

Page 15: ...8 1 25 310P102 Washer Int Tooth Lock 10 2 26 310P136 Screw Mach 1 10 32 x 1 and 1 4 Slpanhd 27 310P149 Screw Mach 1 10 32 x 7 8 Slpanhd 1 28 325P104 Washer Flat 1 4 S S 1 29 325P109 Screw Hxcap 1 4 2...

Page 16: ...ding maximum weight capacity 4 lbs This warranty does not cover water contamination prob lems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problem...