Problem
Possible cause
Corrective Action
unit fails to operate and
control panel lights fail
to signal on.
No power/low power.
Make sure the power is on and the power cord is
locked into place. check the main circuit
breakers.
inoperable electrical outlet.
Plug the power cord into a different outlet of
same amperage rating.
inoperable power switch.
contact your maintenance person or an
authorized service agency.
inoperable Power cord.
Loose connections.
unit fails to heat.
Loose connections.
contact your maintenance person or an
authorized service agency.
inoperable Platen.
Low voltage.
inoperable Hi-Limit thermostat.
inoperable thermocouple.
inoperable solid state Relay.
incorrect amount of water added to
trough in cover.
fill trough in top cover with water before starting
time cycle.
Platen temperature is too low or too
high.
check temperature according to the Maintenance
section of this manual.
Loose connections.
contact your authorized service agency.
unit/table is not level.
Level the table and unit as necessary.
eggs sticking to Platen.
Dirty Platen.
clean Platen.
insufficient butter being used.
Refer to the Operation section of this manual.
Not signaling on “Bacon”
or “Ready”.
inoperable indicator light or audio
signal.
contact your maintenance person or an
authorized service agency.
inoperable control Board.
Loose connection.
Bacon timer is disabled.
enable the Bacon timer according to the
Operation section of this manual