TrOublEshOOTING (continued)

Control Board lEDs

the control Board has three onboard LeDs (figure 

5) to determine the status of the unit and to assist in 

troubleshooting.  

green (Diagnostic)

: the LeD should be off in normal 

operation. However, if any of the 5 potential faults are 

detected by the control Board, this LeD will repeatedly 

blink either 1 through 5 times with a 2 second pause in 

between (refer to the 

Green LED Blink Codes

 section 

below).

yellow (Audio)

: When lit, this LeD indicates that the 

control Board is supplying approximately 10-15 VDc to 

the audio signal.  the audio signal should sound when 

this LeD is lit.

red (heat)

: When lit, this LeD indicates that the 

control Board is calling for heat by supplying VDc to 

terminals 3(+) and 4(-) of the solid state Relay.  When 

off, it means that the grill platen is up to operating  

temperature and satisfied.

green lED Blink Codes

control board 

lED Activity

unit state

condition

the green LeD 

blinks on and off 

1 time, pauses for 

2 seconds, and 

repeats.

the eePROM memory on the control 

Board is corrupted.

in this state, the unit turns off the control signal to the solid 

state Relay and disables all front buttons and lights. the unit 

will not heat up. this continues until the defaults are reloaded 

into memory. to reload the defaults, turn the unit off, press and 

hold the 

TImE 2

 button, turn the unit back on, and release the 

button.

the green LeD 

blinks on and off 

2 times, pauses 

for 2 seconds, and 

repeats.

the ambient temperature within the 

control compartment has exceeded 

155ºf (68ºc).  Verify that there is proper 

air ventilation around the unit and that it 

is not near a significant heat source.

in this state, the unit turns off the control signal to the solid 

state Relay and disables all front buttons and lights.  the unit 

will not heat up. this continues until the ambient temperature 

within the electrical compartment drops below 140ºf (60ºc) 

and the unit is turned off and back on.

the green LeD 

blinks on and off 

3 times, pauses 

for 2 seconds, and 

repeats.

Open or disconnected thermocouple.

in this state, the unit turns off the control signal to the solid 

state Relay and disables all front buttons and lights. the unit 

will not heat up. this continues until the thermocouple is 

reconnected or replaced, and the unit is turned off and back 

on.

the green LeD 

blinks on and off 

4 times, pauses 

for 2 seconds, and 

repeats.

the supply voltage to the unit is below 

160 Vac or above 265 Vac.

in this state, the unit turns off the control signal to the solid 

state Relay and disables all front buttons and front lights.  the 

unit will not heat up.  this continues until the supply voltage is 

within the proper limits and the unit is turned off and back on. 

the green LeD 

blinks on and off 

4 times, pauses 

for 2 seconds, and 

repeats.

the 50/60 Hz signal has been lost due 

to a loose, disconnected, or an open 

wire harness/wiring on the ac isolator 

Board, or from the ac isolator Board to 

the control Board.

in this state, the unit turns off the control signal to the solid 

state Relay and disables all front buttons and lights. the unit 

will not heat up. this continues until the 50/60 Hz signal is 

reapplied and the unit is turned off and back on.

NOTE: During heat mode, this Red lED is very dim, 

so it may be difficult to verify if the Control Board 

is calling for heat.  It is recommended that you 

observe the small round green lED on the Solid 

state relay (figure 6) for mode and diagnostic 

purposes.  When the green lED on the Solid State 

relay is on, it means that the control board is call-

ing for heat.  when off, it means that the control 

Board is NOT calling for heat.  Typically, the VDC at 

the Solid State Relay will be less than 1.0 VDC when 

measured, but may vary because of different quality 

VOms.  Therefore, it is recommended that you do 

NOT attempt to measure the VDC at the Solid State 

relay for diagnostic purposes.

HEAT

BUZZ

STATUS

CR4

CR3

CR5

YELLOW

GREEN

RED

R17

R20

R18

figure 5. control board 

lEDs

figure 6. solid state 

relay

R

PRODUCT SERVICE

TUV

.

gapruit

Bauart

Crouzet

GN

84137220

4/A2-

3-32 VDC

+3/A1

1/L1

2/T1

50 AMP 24-280 VAC

solid state 

Relay 

LeD

Summary of Contents for ES-1200

Page 1: ...P N 1011119 Rev B 03 12 Egg Station Model ES 1200 Owner s Manual Manufacturing Numbers 9300590 A S D L I S T E CM O I N NIT A T...

Page 2: ...e back cover of this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the...

Page 3: ...e agency directory and fill in the information below Authorized Service Agency Name Phone No Address Use only genuine Roundup replacement parts in this unit Use of replacement parts other than those s...

Page 4: ...ical lines protected by fuses or circuit breaker of the proper rating All electrical connections must be in accor dance with local electrical codes and any other applicable codes Warning electrical sh...

Page 5: ...al Cord Plug Configurations Model Mfg No Plug Description Plug Configuration ES 1200 9300590 Power Cord Twist Lock L6 20P Electrical Ratings Model Mfg No Volts Watts Amp Hertz ES 1200 9300590 208 220...

Page 6: ...e use 5 Clean the Service Pans and Side Panel in hot soapy water Rinse in clear water and allow to air dry 6 Reassemble all parts to unit Caution All electrical service connections must be in accordan...

Page 7: ...erature 6 Use the scraper to clean the Grill Surface and move waste into the Grease Catch Pans Operating Procedure Read these instructions prior to cooking eggs 1 Ensure that the unit is set on a leve...

Page 8: ...nd START STOP buttons simultaneously for five seconds The indicator lights will blink 2 Continue to hold the TIME 1 button until the Ready Bacon and Cooking Lights are blinking This sequence means the...

Page 9: ...ent and not covered by warranty The following tips are recommended for maintenance of your stainless steel equipment Always use soft damp cloth for cleaning rinse with clear water and wipe dry When re...

Page 10: ...mperature at the middle of the Platen surface Figure 2 The temperature should be approximately 15 F of 350 F 177 C If temperature is within range proceed to Step 3 If temperature is above or below ran...

Page 11: ...uthorized Service Agency Inoperable Platen Low voltage Inoperable Hi Limit Thermostat Inoperable Thermocouple Inoperable Solid State Relay Incorrect amount of water added to trough in cover Fill troug...

Page 12: ...and back on The Green LED blinks on and off 3 times pauses for 2 seconds and repeats Open or disconnected Thermocouple In this state the unit turns off the control signal to the Solid State Relay and...

Page 13: ...AC 230VAC BOARD SWITCH THERMO COUPLE T4 T3 18 GA TFE 200 C UNLESS OTHERWISE SPECIFIED 22 GA TFE 200 C NOTE ALL WIRES TO BE 14 GA TFE 200 C HEATER GRN GRN YEL BLK BRN WHT BLU POWER CORD T2 T1 P2 P1 P3...

Page 14: ...EGG STATION ES 1200 14 A J Antunes Co P N 1011119 Rev B 03 12 Replacement Parts 10 12 7 3 10 9 14 17 30 32 38 39 40 13 11 5 34 4 37 2 33 42 31 41 36 35 44 6 15 16 8 1 43...

Page 15: ...8 1 25 310P102 Washer Int Tooth Lock 10 2 26 310P136 Screw Mach 1 10 32 x 1 and 1 4 Slpanhd 27 310P149 Screw Mach 1 10 32 x 7 8 Slpanhd 1 28 325P104 Washer Flat 1 4 S S 1 29 325P109 Screw Hxcap 1 4 2...

Page 16: ...ding maximum weight capacity 4 lbs This warranty does not cover water contamination prob lems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problem...

Reviews: