EGG STATION (ES-1200)
12
A.J. Antunes & Co.
P/N 1011119 Rev. B 03/12
TrOublEshOOTING (continued)
Control Board lEDs
the control Board has three onboard LeDs (figure
5) to determine the status of the unit and to assist in
troubleshooting.
green (Diagnostic)
: the LeD should be off in normal
operation. However, if any of the 5 potential faults are
detected by the control Board, this LeD will repeatedly
blink either 1 through 5 times with a 2 second pause in
between (refer to the
Green LED Blink Codes
section
below).
yellow (Audio)
: When lit, this LeD indicates that the
control Board is supplying approximately 10-15 VDc to
the audio signal. the audio signal should sound when
this LeD is lit.
red (heat)
: When lit, this LeD indicates that the
control Board is calling for heat by supplying VDc to
terminals 3(+) and 4(-) of the solid state Relay. When
off, it means that the grill platen is up to operating
temperature and satisfied.
green lED Blink Codes
control board
lED Activity
unit state
condition
the green LeD
blinks on and off
1 time, pauses for
2 seconds, and
repeats.
the eePROM memory on the control
Board is corrupted.
in this state, the unit turns off the control signal to the solid
state Relay and disables all front buttons and lights. the unit
will not heat up. this continues until the defaults are reloaded
into memory. to reload the defaults, turn the unit off, press and
hold the
TImE 2
button, turn the unit back on, and release the
button.
the green LeD
blinks on and off
2 times, pauses
for 2 seconds, and
repeats.
the ambient temperature within the
control compartment has exceeded
155ºf (68ºc). Verify that there is proper
air ventilation around the unit and that it
is not near a significant heat source.
in this state, the unit turns off the control signal to the solid
state Relay and disables all front buttons and lights. the unit
will not heat up. this continues until the ambient temperature
within the electrical compartment drops below 140ºf (60ºc)
and the unit is turned off and back on.
the green LeD
blinks on and off
3 times, pauses
for 2 seconds, and
repeats.
Open or disconnected thermocouple.
in this state, the unit turns off the control signal to the solid
state Relay and disables all front buttons and lights. the unit
will not heat up. this continues until the thermocouple is
reconnected or replaced, and the unit is turned off and back
on.
the green LeD
blinks on and off
4 times, pauses
for 2 seconds, and
repeats.
the supply voltage to the unit is below
160 Vac or above 265 Vac.
in this state, the unit turns off the control signal to the solid
state Relay and disables all front buttons and front lights. the
unit will not heat up. this continues until the supply voltage is
within the proper limits and the unit is turned off and back on.
the green LeD
blinks on and off
4 times, pauses
for 2 seconds, and
repeats.
the 50/60 Hz signal has been lost due
to a loose, disconnected, or an open
wire harness/wiring on the ac isolator
Board, or from the ac isolator Board to
the control Board.
in this state, the unit turns off the control signal to the solid
state Relay and disables all front buttons and lights. the unit
will not heat up. this continues until the 50/60 Hz signal is
reapplied and the unit is turned off and back on.
NOTE: During heat mode, this Red lED is very dim,
so it may be difficult to verify if the Control Board
is calling for heat. It is recommended that you
observe the small round green lED on the Solid
state relay (figure 6) for mode and diagnostic
purposes. When the green lED on the Solid State
relay is on, it means that the control board is call-
ing for heat. when off, it means that the control
Board is NOT calling for heat. Typically, the VDC at
the Solid State Relay will be less than 1.0 VDC when
measured, but may vary because of different quality
VOms. Therefore, it is recommended that you do
NOT attempt to measure the VDC at the Solid State
relay for diagnostic purposes.
HEAT
BUZZ
STATUS
CR4
CR3
CR5
YELLOW
GREEN
RED
R17
R20
R18
figure 5. control board
lEDs
figure 6. solid state
relay
R
PRODUCT SERVICE
TUV
.
gapruit
Bauart
Crouzet
GN
84137220
4/A2-
3-32 VDC
+3/A1
1/L1
2/T1
50 AMP 24-280 VAC
solid state
Relay
LeD