9.4 Phone & Code
Technical data
Dimensions of outdoor unit (W x H x D)
45.5 x 91.5 x 16.0 mm
Operating voltage
9 to 24 V DC
Relay data
24 V DC 125 mA (max.)
Temperature range
Operation: –20 to +60 °C
IP rating
IP54 (outdoor use)
Storage capacity
One master code and up to 18 user codes
Switching duration
1 second
Standards
CE conformity
9.5 Cable junction
Technical data for power supply unit
Cable junction 817028
Cable
H03VV-F 3x1.5 mm
2
Input
230 V AC; 50 - 60 Hz
Output
24 V DC; 2.5 A DC
Degree of protection in accordance with DIN 40050
IP67 (when inserted and only the plug connection between leaf and frame)
Temperature range
When idle: -10 °C to +70 °C
When moving: -10 °C to +50 °C
Standards
CE conformity
9.6 Power supply unit
Technical data
Dimensions of outdoor unit (W x H x D)
78.0 x 93.0 x 56.0 mm
DC voltage
24 V (output)
Rated current
2.5 A (output)
Voltage adjustment range
21.6 to 26.4 V (output)
Voltage range
88 to 264 V AC, 124 to 370 V DC (input)
Frequency range
47 to 63 Hz (input)
Temperature range
Operation: –20 to +60 °C
Relative air humidity
Up to 20 - 90%
Standards
CE conformity
9.7 Day / night changeover switch
Technical data
Line length
5 m
DC voltage
24 V DC
Current consumption
Day: 15 mA
Night: 0 mA
Temperature range
Operation: –20 to +60 °C
Relative air humidity
Up to 20 - 90%
Standards
CE conformity
Technical data
Phone & Code
Subject to change.
Roto Safe E Eneo C | CC | CF
IMO_438_EN_v3
·
05 / 2020
· 87