21
Malfunctions of electrical units
1
The machine
does not work
1. The power cable is damaged
2. Source power is abnormal
3. The ground fault switch is closed
1. Check the power cable
2. Check the working power
3. Open the ground fault
interrupter
2
Ground fault
switch trips
1. Power cable of heating plate, the
motor of pump and planing tool may
be damaged
2. Electrical components are t affected
with damp
3. The higher-up power has not a
ground fault safety device
1. Check the power cables
2. Check the electrical elements.
3. Check the higher-up power
safety device
3
Abnormal
temperature
increasing
1. The temperature controller switch is
open
2. The sensor
(
pt100
)
is abnormal.
The resistance value of4 and 5 of
heating plate socket should be
within 100~183
Ω
3. The heating stick inside heating
plate is abnormal. The resistances
between 2and 3 should be
within23
Ω
. Insulation resistance
between head of heating stick and
outside shell must be more than
1M
Ω
4. Should the temperature controller
readings be more than 300
℃
, which
suggest he sensor may be damaged
or the connection is loosen. Should
the temperature controller indicate
LL, which suggests the sensor have
a short circuit. Should the
temperature controller indicate HH,
which suggests the circuit of sensor
is open.
5. Correct the temperature by button
located on the temperature
controller.
6. The temperature fluctuate
abnormally
1. Check the connection of
contactors
2. Replace the sensor
3. Replace the heating plate
4. Replace the temperature
controller
5. Refer to the methods to set the
temperature
6. Check and replace the
contactors if necessary
4
Lose of control
when heating
The red light is shine, but the
temperature still goes up, that is
because the connector is fault or the
joints 7 and 8 can not open when get
the required temperature.
Replace the temperature controller
5
Planing tool
does not rotate
The limit switch is ineffective or the
mechanical parts of planing tool are
clipped.
Replace the planning tool limit
switch or minor sprocket