17
GB
DC Voltage:
AC Voltage:
Display:
LCD up to 2000, 3 1/2 digits,
Measurement speed:
2 updates per second
Overload indicator:
OL
appears on the display
Polarity indicator:
‘-’ for negative reading
Power source:
2x 1.5V batteries (AAA)
Battery condition
BAT
appears on the display
Working temperature
0°C to +40°C
Storage temperature:
-10°C to +50°C
Humidity:
10% – 95% relative humidity,
non condensing at +30°C
Weight
approx. 135 g without batteries
Dimensions
approx. 105x55x35 mm
Range
Accuracy:
200 mV
± 0.5% ± 3 digits
2,000 V / 200 V / 20 V
± 1.2% ± 3 digits
600 V
Range
Accuracy:
2,000 V / 20 V
± 1.0% ± 8 digits
200 V / 600 V
± 2.3% ± 10 digits
Input impedance:
7.5 MΩ in all ranges
Overload protection:
µA and mA ranges 0.2A / 500 V fast-acting, self
resetting fuse
Input impedance:
7.5 MΩ in all ranges
Frequency range:
50 Hz - 400 Hz
Overload protection:
µA and mA ranges 0.2A / 500 V fast-acting, self
resetting fuse
Display:
RMS of the sine wave
Protection category II
The markings at the terminals indicate that the respective voltages and
currents may not be exceeded!
1500000806_Anleitung_D,GB,F,CZ,H,I,SLO.indb 17
15.07.13 12:53