56
FA ROTEX HPSU monobloc compact • 09/2017
8
x
Errors, malfunctions and messages
E9031
L5
Electrical defect
Electrical components
overvoltage fault
a)
If the fault occurs <15x, the functional safety of the HPSU
monobloc compact is still guaranteed.
Î
Sporadic message during continuous self-monitoring by the
device.
Ɣ
No further measures are required.
b)
If the fault occurs 15x, it is locked and may have the following
causes:
–
Current mains overvoltage.
–
Refrigerant compressor blocked or defective.
–
Inverter circuit board in the heat pump outdoor unit defec-
tive.
–
Wiring, poor contact.
–
Service valves in the heat pump outdoor unit not open.
Ɣ
Check, eliminate cause, replace.
Ɣ
If necessary, contact a ROTEX service technician.
E9032
L8
Electrical components
–
Refrigerant compressor defective.
–
Inverter circuit board in the heat pump outdoor unit defective.
Ɣ
Check, replace.
Ɣ
If necessary, contact a ROTEX service technician.
E9033
L9
–
Refrigerant compressor blocked or defective.
–
Pressure difference between high and low pressure side too
high before starting refrigerant compressor.
–
Service valves in the heat pump outdoor unit not open.
Ɣ
Check, eliminate cause, replace.
Ɣ
If necessary, contact a ROTEX service technician.
E9034
LC
Communication error - internal communication in the heat pump out-
door unit disturbed.
–
Electromagnetic influences.
Ɣ
Perform reset.
–
Main circuit board in the heat pump outdoor unit defective.
–
Inverter circuit board in the heat pump outdoor unit defective.
–
Fan motor defective.
–
Wiring, poor contact.
Ɣ
Check, eliminate cause, replace.
Ɣ
If necessary, contact a ROTEX service technician.
E9035
P1
Circuit board
defective
Inverter circuit board in
the heat pump outdoor
unit
–
No supply voltage from the mains connection.
–
Inverter circuit board in the heat pump outdoor unit defective.
Ɣ
Check, eliminate cause, replace.
Ɣ
If necessary, contact a ROTEX service technician.
E9036
P4
Electrical defect
Temperature sensor
R10T on inverter circuit
board in the heat pump
outdoor unit
Overtemperature in the heat pump outdoor unit
–
Inverter circuit board in the heat pump outdoor unit defective.
–
Temperature sensor on inverter circuit board defective, plug con-
nection X111A not correct.
Ɣ
Check, eliminate cause, replace.
Ɣ
If necessary, contact a ROTEX service technician.
E9037
PJ
Setting output
Output setting for heat
pump outdoor unit incor-
rect
Ɣ
Contact a ROTEX service technician.
E9038
U0
Coolant leak
Sensors and parameter
settings in the heat
pump outdoor unit
Refrigerant loss.
–
Refrigerant quantity too low. See fault code E9015 / E4.
–
Blockage or leak in refrigerant line.
Ɣ
Check, eliminate cause, top up refrigerant.
E9039
U2
Under/over voltage
Mains voltage outside of the permissible range
–
Sporadic fault shortly after a power failure.
Ɣ
No fault elimination necessary.
–
Inverter circuit board in the heat pump outdoor unit defective.
Ɣ
Check, replace.
Ɣ
If necessary, contact a ROTEX service technician.
Code
Malfunction /
error message
Component/
Designation
Causes and possible fault elimination
Display Internal