16
FA ROTEX HPSU monobloc compact • 09/2017
4
x
Set-up and installation
Ɣ
Remove packing and dispose of it in an environment-friendly
manner.
Ɣ
Pull off the cover screens (fig. 4-4, item B) from the storage
tank and unscrew the threaded fittings (fig. 4-4, item F) from
the openings at which the handles are to be fitted (fig. 3-1 to
fig. 3-2, item 24).
Ɣ
Screw the handles (fig. 4-4, item A) into the now uncovered
threaded holes.
Ɣ
Install the ROTEX HPSU monobloc compact at the installa-
tion site.
–
Recommended clearances (fig. 4-5):
From the wall: (s1)
100 mm, (s2)
500 mm.
From the ceiling (X):
1200 mm, at least 480 mm.
–
Transport the ROTEX HPSU monobloc compact using
the handles.
–
When setting up the unit in a cabinet, behind panels or in
other restricted conditions, sufficient ventilation (e.g.,
using ventilation gratings) must be ensured.
Ɣ
If required, install the optional backup heater (BUxx) in the
ROTEX HPSU monobloc compact (fig. 4-5).
Observe the installation and operating instructions enclosed
with the accessories (
tightening torque, see chap. 10.3).
CAUTION!
If the ROTEX
HPSU monobloc compact
is not
installed a
sufficient
distance
below
the flat
solar panels (the top edge of the storage tank is
higher than the bottom edge of the solar pan-
els), the unpressurised solar system in the out-
door area will not be able to drain completely.
Ɣ
Install the ROTEX HPSU monobloc compact
sufficiently low at the flat solar panels
(observe minimum gradient in the solar con-
nection lines) in the case of a DrainBack solar
connection.
A
Handle
B
Cover screen
F
Threaded piece
Fig. 4-4
Installing the handles