IDU-Floor Ceiling 74
2200
-15
TC
17.26
17.26
17.44
17.62
18.13
18.13
18.13
18.13
18.59
18.59
18.59
18.59
19.72
19.72
19.72
19.72
S/T
0.70
0.79
1.00
1.00
0.56
0.65
0.72
0.98
0.50
0.58
0.66
0.73
0.35
0.42
0.49
0.57
PI
3.92
3.92
3.92
3.92
3.91
3.91
3.91
3.91
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
-10
TC
17.16
17.16
17.34
17.52
18.03
18.03
18.03
18.03
18.49
18.49
18.49
18.49
19.66
19.66
19.66
19.66
S/T
0.71
0.80
1.00
1.00
0.56
0.65
0.73
0.98
0.50
0.58
0.66
0.74
0.35
0.43
0.49
0.57
PI
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
3.90
-5
TC
17.06
17.06
17.23
17.41
17.96
17.96
17.96
17.96
18.43
18.43
18.43
18.43
19.61
19.61
19.61
19.61
S/T
0.71
0.80
1.00
1.00
0.57
0.65
0.73
0.99
0.51
0.59
0.66
0.74
0.35
0.43
0.50
0.58
PI
3.90
3.90
3.90
3.90
3.89
3.89
3.89
3.89
3.90
3.90
3.90
3.90
3.91
3.91
3.91
3.91
0
TC
16.97
16.97
17.15
17.33
17.89
17.89
17.89
17.89
18.38
18.38
18.38
18.38
19.59
19.59
19.59
19.59
S/T
0.72
0.80
1.00
1.00
0.57
0.66
0.74
0.99
0.51
0.59
0.67
0.74
0.35
0.43
0.50
0.58
PI
3.91
3.91
3.91
3.91
3.91
3.91
3.91
3.91
3.91
3.91
3.91
3.91
3.92
3.92
3.92
3.92
5
TC
16.88
16.88
17.06
17.24
17.83
17.83
17.83
17.83
18.32
18.32
18.32
18.32
19.57
19.57
19.57
19.57
S/T
0.72
0.81
1.00
1.00
0.57
0.66
0.74
1.00
0.51
0.59
0.67
0.75
0.35
0.43
0.50
0.58
PI
3.95
3.95
3.95
3.95
3.94
3.94
3.94
3.94
3.94
3.94
3.94
3.94
3.95
3.95
3.95
3.95
10
TC
16.78
16.78
16.96
17.13
17.74
17.74
17.74
17.74
18.24
18.24
18.24
18.24
19.52
19.52
19.52
19.52
S/T
0.72
0.81
1.00
1.00
0.57
0.66
0.74
1.00
0.51
0.59
0.67
0.75
0.36
0.44
0.50
0.58
PI
4.02
4.02
4.02
4.02
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
15
TC
16.65
16.65
16.82
16.99
17.62
17.62
17.62
17.62
18.13
18.13
18.13
18.13
19.44
19.44
19.44
19.44
S/T
0.73
0.82
0.90
0.99
0.58
0.67
0.75
0.84
0.52
0.60
0.68
0.76
0.36
0.44
0.51
0.59
PI
4.11
4.11
4.11
4.11
4.10
4.10
4.10
4.10
4.09
4.09
4.09
4.09
4.09
4.09
4.09
4.09
20
TC
16.46
16.46
16.63
16.80
17.43
17.43
17.43
17.43
17.95
17.95
17.95
17.95
19.27
19.27
19.27
19.27
S/T
0.73
0.82
0.90
0.99
0.58
0.67
0.75
0.84
0.52
0.60
0.68
0.76
0.36
0.44
0.51
0.59
PI
4.26
4.26
4.26
4.26
4.24
4.24
4.24
4.24
4.23
4.23
4.23
4.23
4.21
4.21
4.21
4.21
25
TC
15.68
15.68
15.83
16.00
16.66
16.66
16.66
16.66
17.15
17.15
17.15
17.15
18.47
18.47
18.47
18.47
S/T
0.74
0.83
0.92
1.00
0.59
0.68
0.76
0.85
0.52
0.60
0.69
0.78
0.36
0.44
0.52
0.60
PI
4.69
4.69
4.69
4.69
4.68
4.68
4.68
4.68
4.68
4.68
4.68
4.68
4.69
4.69
4.69
4.69
30
TC
14.94
14.94
15.08
15.22
15.88
15.88
15.88
15.88
16.37
16.37
16.37
16.37
17.64
17.64
17.64
17.64
S/T
0.75
0.85
0.94
1.00
0.59
0.68
0.78
0.87
0.52
0.61
0.70
0.79
0.35
0.44
0.52
0.60
PI
5.13
5.13
5.13
5.13
5.14
5.14
5.14
5.14
5.15
5.15
5.15
5.15
5.17
5.17
5.17
5.17
35
TC
14.19
14.19
14.33
14.48
15.11
15.11
15.11
15.25
15.60
15.60
15.83
15.60
16.80
16.80
16.80
16.80
S/T
0.76
0.86
0.96
1.00
0.60
0.70
0.79
0.89
0.52
0.62
0.71
0.81
0.35
0.44
0.53
0.61
PI
5.61
5.61
5.61
5.61
5.63
5.63
5.63
5.63
5.64
5.64
5.65
5.64
5.68
5.68
5.68
5.68
40
TC
13.38
13.43
13.56
13.69
14.26
14.26
14.26
14.41
14.72
14.72
14.85
14.72
15.89
15.89
15.89
15.89
S/T
0.79
0.90
1.00
1.00
0.61
0.72
0.82
0.93
0.53
0.63
0.74
0.84
0.34
0.44
0.54
0.90
PI
6.19
6.19
6.19
6.19
6.22
6.22
6.22
6.22
6.23
6.23
6.24
6.23
6.28
6.28
6.28
6.28
46
TC
12.39
12.51
12.62
12.74
13.23
13.23
13.23
13.37
13.66
13.66
13.66
13.66
14.78
14.78
14.78
14.78
S/T
0.80
0.91
1.00
1.00
0.62
0.73
0.84
0.95
0.53
0.64
0.75
0.86
0.34
0.44
0.54
0.92
PI
6.89
6.89
6.89
6.89
6.92
6.92
6.92
6.92
6.94
6.94
6.94
6.94
7.00
7.00
7.00
7.00
50
TC
11.62
11.73
11.85
11.96
12.42
12.42
12.42
12.54
12.85
12.85
12.85
12.85
13.92
13.92
13.92
13.92
S/T
0.82
0.94
1.00
1.00
0.63
0.75
0.86
0.98
0.54
0.65
0.77
0.88
0.34
0.44
0.55
0.97
PI
7.46
7.46
7.46
7.46
7.49
7.49
7.49
7.49
7.51
7.51
7.51
7.51
7.57
7.57
7.57
7.57
TC:Total Cooling Capacity (kW)
S/T:Sensible Cooling Capacity Ratio
PI:Power Input(kW)
Note: The table shows the case where the operation frequency of a compressor is fixed.
Summary of Contents for ANERU Series
Page 2: ......
Page 5: ......
Page 6: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Page 12: ...Contents 1 Model Reference 2 2 External Appearance 3 Model Reference...
Page 15: ...Model Reference 4 2 2 Outdoor Unit Single Fan Outdoor Unit Double Fan Outdoor Unit...
Page 18: ...IDU Console 3 2 Dimensional Drawings 16 Drain pipe Hanging arm 195 700 600 210...
Page 21: ...IDU Console 6 6 Air Velocity and Temperature Distributions Discharge Angle 60...
Page 36: ...IDU Compact Cassette 4 2 Dimensional Drawings...
Page 38: ...IDU Compact Cassette 6 4 Service Place...
Page 56: ......
Page 115: ...IDU Super Slim Casstte 54 36k 42k 48k 55k...
Page 118: ......
Page 131: ...IDU Duct 7 6 Fan Performance 12K...
Page 132: ...IDU Duct 8 18K...
Page 133: ...IDU Duct 9 24K...
Page 134: ...IDU Duct 10 30K 36K...
Page 135: ...IDU Duct 11 42K 48K...
Page 136: ...IDU Duct 12 55K...
Page 165: ...IDU Duct 41 12k 18k 24k 30k...
Page 166: ...IDU Duct 42 36k 42k 48k 55k...
Page 178: ......
Page 179: ...35mm 1 38in...
Page 180: ......
Page 256: ...IDU Floor Ceiling 82 36k 48k 55k...
Page 259: ......
Page 267: ...Outdoor Unit 3 Panel Plate B30...
Page 268: ...Outdoor Unit 4 Panel Plate BA30...
Page 269: ...Outdoor Unit 5 Panel Plate CA30...
Page 270: ...Outdoor Unit 6 Panel Plate D30...
Page 271: ...Outdoor Unit 7 Panel Plate X230...
Page 272: ...Outdoor Unit 8 Panel Plate X330...
Page 273: ...Outdoor Unit 9 Panel Plate X430...
Page 274: ...Outdoor Unit 10 Panel Plate E30...
Page 275: ...Outdoor Unit 11 Panel Plate 590...
Page 276: ...Outdoor Unit 12 2 Service Place...
Page 285: ...Outdoor Unit 21 UO70Xo UO90Xo UO100Xo UO100Xo3F...
Page 286: ...Outdoor Unit 22 UO120Xo UO140Xo UO160Xo...
Page 291: ......
Page 292: ......
Page 293: ......
Page 294: ......
Page 295: ...Outdoor unit printed circuit board diagram 17122000044714 17122000048121 17122000046453...
Page 297: ...Outdoor unit printed circuit board diagram 17122000048064...
Page 299: ...Outdoor unit printed circuit board diagram 17122000047742 1 3 4 6 8 9 5 7 10 12 11 2 13...
Page 302: ...Outdoor unit printed circuit board diagram 17122000041841...
Page 304: ...Outdoor unit DC motor driver board diagram 17122000021912 5 6 1 2 3 4...
Page 320: ...3 IDU Installation Duct Connector Connector...
Page 352: ...Product Features 13 Remote LCD Screen Indicators...
Page 549: ......
Page 550: ......
Page 551: ......
Page 552: ...email info rotenso com www rotenso com INSTALLER STAMP...