Dimming Control
MDR-42
- 77 -
ROTEC technology
Single values :
- Minimal temperature Backlight on :
The backlight will not switch on of the actual temperature is under this minimal
temperature. The backlight will not switch off when the actual temperature become lower
then the minimal value during operation.
- Maximal temperature Backlight off :
The backlight is switched of when the temperature comes higher then the maximum
temperature.
- Temperature Fan group 1 :
The fan group 1 is switch on when the actual temperature is higher then defined
- Temperature Fan group 2 :
The fan group 2 is switch on when the actual temperature is higher then defined
- Timeout Watchdog :
Intervall time of watchdog. The CPU will be reset if the watchdog will not triggered from
Dimming Control
- Timeout Aplication Software :
This parameter defines the the intervall time the application software has to send an
heartbeat (WM_HEARTBEAT).
- Offset Backlight :
Offset for backlight
– brightnes ( 0 … 100 % )
- Fix Backlight :
Value for backlight if backlight fix ist active ( 0 … 100 % )
- Temperature Range Fangroup 1 / 2
( 0 … 15 ) :
Temperature T
Range
for 100 % Fanspeed