![Rosslare AYC-E 5 Series Installation And Programming Manual Download Page 61](http://html.mh-extra.com/html/rosslare/ayc-e-5-series/ayc-e-5-series_installation-and-programming-manual_1489260061.webp)
Technical Specifications
AYC-Ex5/T65 Series Installation and Programming Manual
61
5.
Technical Specifications
Specification
AYC-E55
AYC-E65B,
AYC-E65BB
AYC-T65
Electrical Characteristics
Power Supply Type
Linear type (recommended)
Operating Voltage
Range
5–16 VDC (when used as a controller, provided by the
secured intelligent power supply)
Input Current
Standby
15 m A@12 VDC
92 mA @12 VDC
Max Input Current
40 mA @16 VDC
105 mA @16 VDC
LED Control Input
Dry contact N.O.
Tamper Output
Open collector, active low, 30 mA max sink current
Cable Distance to
Host Controller
Up to 500 ft. (150 meters) using an 18 AWG cable
Max. Proximity Card
Read Range*
N/A
40 mm (1.6 in.)
Proximity Card
Modulation
N/A
ASK at 125 kHz
Proximity Card
Compatibility
N/A
EM cards
Card Transmit
Format (Reader)
N/A
Wiegand 26-Bit, or Clock & Data
Keypad Transmit
Format (Reader)
Programmable PIN code formats
LED Indicators
Two tri-colored LEDs
Communication
Data1/C1, Data0/C2 — open collector, 5 V
termination
* Measured using a Rosslare proximity card or equivalent. Range also