Controller Operation
AYC-Ex5/T65 Series Installation and Programming Manual
45
on the second door. The REX feature for the second door is not
enabled when using this mode.
The auxiliary setting defines the door open time for the second
door. The auxiliary input can switch the mode of operation of the
controller between Normal and Secure modes. By connecting a
switch timer or alarm system output to the auxiliary input, the
controller can be automatically switched from Normal mode
(during office hours) to Secure mode (after office hours).
4.9.9.3
Auxiliary Mode 2
Auxiliary input function:
Toggles Normal/Secure modes
Auxiliary output activated by:
Bell Button (
)
For example, in Auxiliary Mode 2, the auxiliary relay can function as
a general purpose time switch that can be activated when
is
pressed. The auxiliary setting establishes for how long the auxiliary
relay is to be activated. The auxiliary input can switch the mode of
operation of the controller between Normal and Secure modes. By
connecting a switch timer or alarm system output to the auxiliary
input, the controller can be automatically switched from Normal
mode (during office hours) to Secure mode (after office hours).
4.9.9.4
Auxiliary Mode 3
Auxiliary input function:
Toggles Normal/Secure modes
Auxiliary output activated by:
Alarms
For example, in Auxiliary Mode 3, the auxiliary output is activated if
the controller is tampered; that is, if the case is forcibly opened or
removed from the wall. The auxiliary input can switch the mode of
operation of the controller between Normal and Secure modes. By
connecting a switch timer or alarm system output to the auxiliary
input, the controller can be automatically switched from Normal
mode (during office hours) to Secure mode (after office hours).
4.9.9.5
Auxiliary Mode 4
Auxiliary input function:
Toggles Normal/Secure modes
Auxiliary output activated by:
direct shunt (explanation below)