Technical Specifications
10
AYC-B7661 Installation Manual
2.
Technical Specifications
General Characteristics
Output Formats
•
Wiegand 26 (default)
•
Wiegand 26 with Facility code
•
Wiegand 32 Reversed
•
Clock & Data
•
Wiegand 32
•
Wiegand 34
•
Wiegand 40
Max. Read Range*
4 cm (1.6 in.)
Electrical Characteristics
Power Supply Type
Linear type (recommended)
Input Voltage
5 to 16 VDC
Absolute Maximum
(non-operating)
18 VDC
Maximum Input Current
(1:1)
Standby: 60 mA @ 12 VDC
Read: 100 mA @ 12 VDC
Maximum Input Current
(1:N)
Standby: 95 mA @ 12 VDC
Read: 100 mA @ 12 VDC
Tamper Output
Open collector, active low
Max. sink current 32 mA
Maximum Controller Cable
Distance
150 m (500 ft.)
(using 18-AWG shielded cable)
Frequency
13.56 MHz
Card Compatibility
MIFARE
ISO14443A-3 standard
* Measured using a Rosslare proximity card or equivalent. Range
also depends on electrical environment and proximity to metal.