Communications
RS-232
MD-N32
Access
Control
Panel
LAN/WAN
Figure 19: MD-N32 Configuration connecting a single panel
When using an MD-N32, for a single panel, either an RS-232
cable or Rosslare's MD-14 RS-485 converter can be used.
To connect an MD-N32 to more than one panel (up to 32
panels), Rosslare's MD-14 RS-485 converter must be used.
Connect the MD-14 between the RS-485 access control panel
network and the MD-N32 converter.
RS-232
MD-N32 TCP/IP/
RS-232 Converter
MD-14 RS-232/
RS-485 Converter
RS-485
RS-485
Access
Control
Panel #1
Access
Control
Panel #2
LAN/WAN
Figure 20: Connecting Multiple Access control panels with MD-N32
The MD-14 is not required when using the AC-225IP.
AC-225IP
RS-485
RS-485
Access
Control
Panel #1
Access
Control
Panel #2
LAN/WAN
Figure 21: Connecting Multiple Access control panels with AC-225IP
Note:
For more information on operating an MD-N32, refer to
the MD-N32 User Manual.
AC-225 Hardware Installation and User Guide
Page 37