78 • Monitoring
RCP-ME User Guide (v4.0)
Troubleshooting
This section provides general information and tips for troubleshooting.
Loading the Factory Defaults via DashBoard
If you need to return the RCP-ME to a known configuration, you can use DashBoard to load the factory defaults.
This defaults the RCP-ME panel configuration (Panel Config interface settings) only, and not the connection
configuration (Connection Editor).
To load the factory defaults
1. Open the RCP-ME Panel Config interface (see “
To open the RCP-ME Panel Config interface
2. Select the
Configuration
tab.
3. In the
Configuration
section, select the
Load Factory Defaults
check box.
Ensure that only the
Home
page box is selected in the
Send Configuration
dialog. De-select all other pages or
they will be sent to the device as well, thus changing the factory defaults.
4. Send the current configuration file to the device (see “
To send the current configuration to a panel
The factory defaults are loaded.
Upgrading the Software
The RCP-ME can be upgraded in the field via DashBoard. Note that DashBoard version 8.2.0 or higher is required
for this procedure.
Contact Ross Technical Support for the latest software file for the RCP-ME.
Checking the Firmware Version
Firmware may be updated easily using DashBoard. To check for the latest firmware versions, contact Ross Video
Technical Support.
Table 15.1 Troubleshooting
Problem
Cause
Action
I am stuck on a menu
with no way back.
A return loop was not set up
when the menu was defined.
Use DashBoard to return to the Home menu.
RCP-ME is not
responding to
DashBoard.
Information stored in the
RCP-ME has been corrupted.
Try the following until the RCP-ME responds:
• Reset the RCP-ME
• Send the default configuration file to the RCP-ME
• Load the factory defaults via DashBoard.
The RCP-ME is not
switching correctly.
The NK Series devices are not
set up correctly to operate with
or without virtual routing.
Use DashBoard to set up the devices with virtual routing
enabled or disabled as required.
I get a
PROT
BRKWY ERR
when
I press the
Protect
button.
At least one crosspoint across
the router levels defined in the
current breakaway does not
exist.
Determine which level is causing the breakaway warning and
then:
• connect the source and destination equipment so that the
particular crosspoint will work, or
• remove the router level from the breakaway definition.
Summary of Contents for Ultricore RCP-ME
Page 1: ...RCP ME User Guide...
Page 6: ......
Page 10: ...iv Contents RCP ME User Guide v4 0...
Page 14: ...14 Introduction RCP ME User Guide v4 0...
Page 28: ...28 Getting Started RCP ME User Guide v4 0...
Page 54: ...54 Macros RCP ME User Guide v4 0...
Page 56: ...56 Salvos RCP ME User Guide v4 0...
Page 60: ...60 Category Index Mode RCP ME User Guide v4 0...
Page 70: ...70 Linking Remote Control Panels RCP ME User Guide v4 0...
Page 72: ...72 Cutbus Mode RCP ME User Guide v4 0...
Page 76: ...76 Managing Panel Configurations RCP ME User Guide v4 0...
Page 80: ...80 Monitoring RCP ME User Guide v4 0...
Page 94: ...94 DashBoard Interface Overview RCP ME User Guide v4 0...
Page 96: ...17 96 RCP ME Hexadecimal to Router Level Conversion RCP ME User Guide v4 0...