RCP-ME User Guide (v4.0)
Functions • 47
5. Close the
Button
dialog.
The simulated RCP-ME in DashBoard shows the type of shift and shift page on the selected button. For
example,
SRC SH2
.
6. Send the current configuration file to the device (see “
To send the current configuration to a panel
page 74).
Assigning a Protect Button
To prevent switching of critical crosspoints by others, assign a protect button for use on the RCP-ME. The protect
function ensures that the selected destination can only receive the selected source across the selected levels. Once
protected, the selected levels on a destination cannot be switched by other remote control panels (or by the same
remote control panel if
Block All Panels
is selected). The source is not protected and can be freely routed to other
destinations if required. You can protect any number of destinations.
You can also use the protect button to lock the RCP-ME against all button presses (see “
To assign a protect button using DashBoard
1. Open the RCP-ME Panel Config interface (see “
To open the RCP-ME Panel Config interface
2. On the simulated RCP-ME, click the button that you want to use for the level.
The
Button
dialog opens.
3. In the
Button
list, select
Function Key
.
4. In the
Value
list, select
Protect
as the function to assign to this button.
5. Close the
Button
dialog.
The simulated RCP-ME in DashBoard shows the protect (
PROT
) on the button.
6. Select the
Configuration
tab.
7. In the
Configuration
section, select the mode of protection that you want to use for the protect button. Use the
information in
as a guide:
8. Send the current configuration file to the device (see “
To send the current configuration to a panel
page 74).
Assigning a Take Button
If you want to pre-load a switch sequence but delay the switch, assign a take button on the menu. If a take button is
assigned, then all switches on that menu are activated by pressing the
TAKE
button instead of the
source/crosspoint/macro button. You should assign a take button on each menu that requires this switching type.
Table 6.1 Protect Mode Descriptions
Protect Mode
Description
Block Other
Panels
The protected destination and level(s)
cannot
be switched to another source
by other remote control panels.
The protected destination and level(s)
can
be switched to another source on
the current remote control panel.
Block All Panels
The protected destination and level(s)
cannot
be switched to another source
by the current remote control panel or other remote control panels.
Summary of Contents for Ultricore RCP-ME
Page 1: ...RCP ME User Guide...
Page 6: ......
Page 10: ...iv Contents RCP ME User Guide v4 0...
Page 14: ...14 Introduction RCP ME User Guide v4 0...
Page 28: ...28 Getting Started RCP ME User Guide v4 0...
Page 54: ...54 Macros RCP ME User Guide v4 0...
Page 56: ...56 Salvos RCP ME User Guide v4 0...
Page 60: ...60 Category Index Mode RCP ME User Guide v4 0...
Page 70: ...70 Linking Remote Control Panels RCP ME User Guide v4 0...
Page 72: ...72 Cutbus Mode RCP ME User Guide v4 0...
Page 76: ...76 Managing Panel Configurations RCP ME User Guide v4 0...
Page 80: ...80 Monitoring RCP ME User Guide v4 0...
Page 94: ...94 DashBoard Interface Overview RCP ME User Guide v4 0...
Page 96: ...17 96 RCP ME Hexadecimal to Router Level Conversion RCP ME User Guide v4 0...