1.  General Information 

 

This Operating Manual is valid for the Calibration Kits  

 

74CK011-170 (Industrial Version)

 

 

Customer specific F 75 

 Calibration Kits

 

 

 

 

1.1 Calibration Kit Normal Use 

 

Calibration Kits are used as an accessory for VNAs to perform vector-error correction. Vector-error 
correction  is  the  process  of  characterizing  systematic  errors  of  the  measurement  system  by 
measuring  known  calibration  standards,  and  then  mathematically  removing  the  effects  of  these 
errors  from  subsequent  measurements.  The  measurement  accuracy  of  the  calibrated  VNA 
depends  mainly  on  the  quality  of  the  calibration  kit  used.  Contributing  factors  are  noise,  linearity 
and  temperature  stability  of  the  VNA,  transmission  and  reflection  stability  of  a  test  port  cable  as 
well as operator experience and care. 

 

VNAs  usually  offer  several  techniques  for  correcting  systematic  measurement  errors.  The 
standards  in  this  calibration  kit  allow  you  to  perform  one-port  OSL  (OSM)  or  two-port  OSLT 
(TOSM)  and  TRM  (TMR)  calibrations  from  DC  up  to  6  GHz  for  measurements  of  Rosenberger 
components with F 75 

 connectors. 

 

Components with other F 75 

 connectors are mechanically compatible and can also be measured 

if they are designed according to IEC 169-24 or EIA-550. 

 

 
1.2 Warnings 

 

The  calibration  standards  of  this  calibration  kit  are  mechanically  sensitive  devices.  High 
accelerations e.g. when falling down will damage them.  

 

Connect the calibration standards only to test ports and other devices that have been cleaned and 
checked for gauge, concentricity and integrity of the contact fingers. Detailed procedures are 
described in Chapter 6 and 7.  

 

Tighten  the  connector  coupling  nuts  to  the  recommended  torque  with  the  torque  wrench.  Do  not 
over torque! 

 

Consider the power applied to the Load calibration standards. Maximum power limits for the sum of 
RF and DC power are defined in the specific data sheets. 

 

It  is  good  lab  practice  to  use  at  least  an  ESD  wrist  strap  when  handling  calibration  standards  or 
DUTs  on  a  VNA  although  the  calibration  standards  themselves  are  not  ESD  sensitive.  Please 
consult your VNA manual. 

 

Follow further limitations given in the specific data sheets. 
 

Connect calibration standards and adapters of this calibration kit only to counterparts that 
are  designed  according  to  IEC  169-24  or  EIA-550.  Incompatible  connector  dimensions  will 
damage them.

 

 

Summary of Contents for 74CK011-170

Page 1: ...hnik GmbH Co KG P O Box 1260 D 84526 Tittmoning Germany www rosenberger com Tel 49 8684 18 0 Email info rosenberger com Page 1 15 Dieses Dokument ist urheberrechtlich gesch tzt This document is protec...

Page 2: ...4 Calibration Certificate 1 5 2 Specifications Environmental Requirements 2 1 Electrical and mechanical Specifications 2 2 3 Standard Definitions Standard Definitions 3 1 Installation of Standard Defi...

Page 3: ...his calibration kit allow you to perform one port OSL OSM or two port OSLT TOSM and TRM TMR calibrations from DC up to 6 GHz for measurements of Rosenberger components with F 75 connectors Components...

Page 4: ...a 74K12L 001S3 1 Short circuit plug 74S12S 001S3 1 Short circuit jacka 74K12S 001S3 1 Calibration load plug 74S150 C11S3 1 Calibration load jacka 74K150 C11S3 1 Calibration Adaptor plug plug 74S121 S2...

Page 5: ...PNA Keysight Agilent and ZVA Rohde Schwarz Calibration Certificate as PDF file Standard Definitions Cards Printed Standard Definitions that can be used on nearly all Vector Network Analyzers Kit Info...

Page 6: ...ure range for which the specifications are valid is defined in the specific data sheets 2 2 Electrical and mechanical Specifications Electrical and mechanical specifications are defined for all calibr...

Page 7: ...a more complex process Please consult the VNA operating manual Some network analyzers allow a step by step input of the model based standard definitions during the VNA calibration without previously l...

Page 8: ...thmic Sweep range start frequency stop frequency Number of points frequency step size Source power IF bandwidth small IF bandwidth basically increases the dynamic range Sweep time Connect test port ca...

Page 9: ...ilable In cases when the two VNA test ports have different connector systems installed e g RPC N 75 and F 75 UOSM can handle this situation A second calibration kit is needed Calibration Procedure Ada...

Page 10: ...cal Rosenberger sales office Please use the Service Form at the end of this manual if there are any known problems with your calibration kit 5 4 Extent of Rosenberger Re Calibration Services Every cal...

Page 11: ...s will usually also have raised edges around them and will make less than perfect contact further to this raised edges on mating interfaces will make dents in other connectors to which they are mated...

Page 12: ...olvents directly on to the connector surfaces or use contaminated solvents Use the low pressure compressed air once again to remove any remaining small particles and to dry the surfaces of the connect...

Page 13: ...grity non destructive mating and electrical performance of the connector The mechanical gauging of coaxial connectors will detect and prevent the following problems Inner conductor protrusion This may...

Page 14: ...ways wear a grounded wrist strap and work on a grounded conductive table mat 2 Visually inspect the connectors 3 If necessary clean the connectors Refer to 4 1 Connector Care 4 Check connector gage ac...

Page 15: ...onnecting a sliding load leave the centre conductor pullback handle in the locked position Use the combi wrench to prevent the device body from turning Use torque wrench to loosen the connecting nut C...

Reviews: