5. Hit the enter key. The box is now operational and port 1 is selected. The
flash procedure is complete.
You may receive any of the following error messages when receiving the
file:
Checksum error
or
Record error
or
Data error
Receive failed
Try again Y/N?
If any of these errors occur, it means the RS232 cable is bad, the RS232
protocol is not configured correctly, or there are bad transmit or receive
levels, or there are hardware problems on either the receiver or transmitter
end. Only three wires are necessary to the UltraView, transmit, receive and
ground. Enter Y to try again and it takes you back to the beginning
Waiting
for file ...
Enter N and the box will prompt you
Hit enter to boot
which brings
you to the same point as step 4, with the firmware unchanged.
If verifying fails, the box should be serviced. You can try to program the flash
again though by hitting enter.
Verify failed
Hit enter to program
Method 2 - Using the LEDs and front panel switches with a file copy
1. Connect the RS232 cable from your computer’s serial port to the RS232
port on the unit.
2. Press both the - and + switches on the front panel, at power-on of the
UltraView. The UltraView is ready to accept the upgrade file at 9600 baud as
shown by LED 1 being lit. To use 57600 baud, press the + switch, LED 4 will
light. Before loading the file you can always change between the baud rates
by pressing the - switch (9600 baud, LED 1 lit) or the + switch (57600 baud,
LED 4 lit).
3. Copy the file to the unit. While the file is being copied LED 1 or 4 will flash.
Once the file is copied, LED 2 will light.
4. Press and release the + switch, LED 2 flashes off for a brief instant. The
flash is now being programmed and verified. LED 3 now lights.
5. Press and release the + switch, LED 3 flashes off for a brief instant. The
new firmware is now run and diagnostic information is sent to the on-screen
display. Observe the new revision number matches that of the file. LED 4
now lights.
6. Press and release the + switch. LED 1 now lights. The box is now
operational and port 1 is selected. The flash loading procedure is complete.
35
ULTRAVIEW INSTALLATION AND OPERATION MANUAL
Summary of Contents for UltraView
Page 2: ......
Page 50: ......
Page 51: ......
Page 52: ...ELECTRONICS 10707 STANCLIFF ROAD n HOUSTON TEXAS 77099 n TEL 281 933 7673 ...