Unit functions
Page 22
RESM-5
8.5
Basic functional test on the
RESM-5
To prevent dangerous situations, refer to the
information provided in the ROPEX Applica-
tion Report and the risk analysis for the machine or
plant.
1. Connect the temperature controller and the
RESM-5 in accordance with the wiring diagram.
2. Start up the temperature controller and the RESM-5
(refer to the documentation for the controller and the
RESM-5).
3. Select the required SET temperature using the tem-
perature controller (refer to the risk analysis for the
machine or plant).
4. Specify a maximum temperature which is less than
the SET temperature of the temperature controller
with step 206 in the Settings menu on the RESM-5
(refer to the risk analysis for the machine or plant).
5. Activate the START signal on the temperature cont-
roller.
6. If the maximum temperature set on the RESM-5 is
exceeded, an alarm must appear on the display and
the alarm output must be energized/switched.
The complete functional test must be carried
out in accordance with the risk analysis for
the machine or plant.
9
Unit functions
See also section 7.3 "Wiring diagram" on page 17.
9.1
LEDs and controls
!
!
12
13
14
15 16
17
18
9
8
6
5
10 11
7
4
3
2
1
www.ROPEX.de
R
“MENU” key for “Next step” and
“Change menu”
Press < 1 s: Next step
Press 1-2 s: Previous step
Press > 2 s (Hold):
Back to home position
ENTER function:
RESET function:
"ENTER” key
Save values
“Reset” after alarm
“UP” and “DOWN” keys for setting values
Press (< 2 s): Change in small steps
Hold (> 2 s): Fast scroll
OLED display, several lines, multilingual