Installation
Page 14
RESM-5
7
Installation
See also section 1 "Safety and warning notes" on
Installation and startup may only be
performed by technically trained, skilled
persons who are familiar with the associated risks
and warranty provisions.
7.1
Installation procedure
Proceed as follows to install the RESISTRON
monitoring device RESM-5:
1. Switch off the line voltage and verify that the circuit
is de-energized.
2. The supply voltage specified on the nameplate of
the RESISTRON monitoring device must be
identical to the line voltage that is present in the
plant or machine. The line frequency is
automatically detected by the temperature controller
in the range from 47Hz to 63Hz.
3. Install the RESISTRON monitoring device in the
front panel cutout. It is fastened by means of two
clips which snap onto the side of the controller
housing.
4. Wire the system in accordance with the instructions
in section 7.3 "Wiring diagram" on page 17,
section 7.3 "Wiring diagram" on page 17, and the
ROPEX Application Report. The information
provided in section 7.2 "Installation steps" on
page 15 must also be heeded.
Check the tightness of all system
connections, including the terminals for the
impulse transformer windings.
5. Make sure the wiring conforms to all relevant
national and international installation regulations.
To prevent dangerous situations, refer to the
risk analysis for the machine or plant.
!
!
!