CANopen
Page 68
RES-5009
Version 1
The meaning of the bits is described in
section 9.2 "Input data" on page 30.
10.7.7 Status information
The “Status” object 4203
h
/00 contains various bit-coded information, which reflect the status of theRESISTRON
®
Temperature Controller RES-5009:
The meaning of the bits is described in
section 9.3 "Output data" on page 34.
10.7.8 Manufacturer Status Register 1002
h
In the Manufacturer Status Register (CANopen object 1002h), the status of the RESISTRON
®
Temperature Con-
troller RES-5009 can be read out. The 32 bit value is a combination of ROPEX error number (object 4203
h
,
section 9.15 "Error messages" on page 49) and status information (4204
h
,
section 10.7.7 "Status informa-
Reserve
Active channel
Status information
Name:
0
0
0
MU
CH2
CH1
CH0
SA
IA
WA
AA
AG
AL
TE
TO
RA
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Bit
Meaning
MU
Measurement interruption
CH0…CH2
active channel
SA
Standby active
IA
Information active
WA
Warning active
AA
AUTOCAL active
AG
AUTOCAL blocked
AL
Alarm active
TE
Temperature reached
TO
Temperature OK
RA
Control active
ROPEX error number
Name:
0
0
0
0
0
0
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
Bit no.:
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Reserve
Active channel
Status information
Name:
0
0
0
MU
CH2
CH1
CH0
SA
IA
WA
AA
AG
AL
TE
TO
RA
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0