Device functions
Page 52
RES-5009
Version 1
Part 2 of 3: Error messages (warnings)
NOTE:
The specified error messages are first output as warnings:
• Actual value output changes between two values
• Alarm LED blinks quickly
• Alarm relay is not active
After activation of the START signal, the output occurs as a fault:
• Actual value output does not change any more, see bold italic values
• Alarm LED lights up continuously
• Alarm relay is active
Error no.
Actual
value
outp.
Voltg. [V]
Cause
Measure during initial
startup
Measure during
machine operation,
heating element not
changed
8
104
5.33
10
Current signal incorrect
Impulse transformer incor-
rectly sized
Perform
AUTOCAL,
Check transformer speci-
fication,
Error ranges
Error ranges
(“Loose contact”)
105
Voltage signal incorrect
Impulse transformer incor-
rectly sized
Strong harmonic waves on
power supply
106
Voltage and current signal
incorrect
Impulse transformer incor-
rectly sized
302
Temperature too low
Calibration not performed
Loose contact
Ambient temperature fluctu-
ates
Perform
AUTOCAL
and/or
Error ranges
(“Loose contact”)
303
Temperature too high
Calibration not performed
Loose contact
Ambient temperature fluctu-
ates
9
211
6.00
10
Data error
Perform
AUTOCAL
Perform
AUTOCAL