CANopen
Page 66
RES-5009
Version 1
10.7.4 Output data
10.7.5 Runtime data
CAUTION
In case of write access, the runtime data are directly stored retentively. When the device is
restarted, the runtime data are retained.
Index
Name
Acc
ess
Standard
value
Range of values
Data
type
4200
h
Actual temperature
RO
-
-99…999 °C
INT16
4201
h
Start temperature
RO
-99
-99…999 °C
INT16
4202
h
Device temperature
RO
-
-60…190 °C
INT16
4203
h
Status
(
section 10.7.7 "Status information" on
RO
UINT16
4204
h
Error number
(
section 9.15 "Error messages" on
RO
-
-
UINT16
Index
Name
Acc
ess
Standard
value
Range of values
Data
type
4300
h
System date
(
section 10.17 "Date and time in CAN-
RW
-
-
UINT32
4301
h
System time
(
section 10.17 "Date and time in CAN-
RW
-
-
UINT32
4302
h
Operating hours (in 0.1 h)
RO
0 (0.0 h)
0…999999999
(0…99999999.9 h)
UINT32
4303
h
non-resettable total cycles counter
RO
0
0…999999999
UINT32
4304
h
Resettable total cycles counter
RW
0
0…999999999
UINT32
4305
h
Cycle counter
Sub index 1: Channel 0
…
Sub index 8: Channel 7
RW
0
0…999999999
UINT32
Summary of Contents for RESISTRON RES-5009